Rapid Determination of Creatinine in Human Urine by Microchip Electrophoresis with LED Induced Fluorescence Detection

被引:21
作者
Wang, Shuping [1 ]
Li, Xinchun [1 ]
Yang, Jianping [1 ]
Yang, Xiujuan [1 ]
Hou, Fenghua [1 ]
Chen, Zuanguang [1 ]
机构
[1] Sun Yat Sen Univ, Sch Pharmaceut Sci, Higher Educ Mega Ctr, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Microchip electrophoresis; Fluorescence detection; Light-emitting diode (LED); Creatinine; Urine; MICROFLUIDIC CHIP ELECTROPHORESIS; PERFORMANCE LIQUID-CHROMATOGRAPHY; CAPILLARY-ZONE-ELECTROPHORESIS; CONDUCTIVITY DETECTION; DIODE-ARRAY; SERUM; ACID; METABOLITES; MARKERS; SYSTEM;
D O I
10.1007/s10337-012-2324-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In clinical medicine, urine creatinine concentration is an important marker in the evaluation of renal function and muscular dysfunctions. Herein, we reported a novel method for rapid determination of creatinine in urine by microchip electrophoresis with light-emitting diode induced fluorescence detection. Creatinine was derivatized by fluorescein isothiocyanate, and then quantitatively detected by the developed microchip LED induced fluorescence detection system. The excitation and emission wavelengths were 490 and 523 nm, respectively. The urine samples were analyzed after centrifuge and filtration. A baseline separation was obtained in < 30 s using 10 mM borate buffer (pH 9.0, containing 45 mM sodium dodecylsulfate), with separation voltage of 1.5 kV. Good linearity was obtained (r (2) = 0.9978) in the concentration range of 10.0-2.00 x 10(3) mu M, and the limit of detection was 2.87 mu M (S/N = 3). The recovery was 96.0-107 %, and the interday precision was < 4.5 % (n = 6). To validate assay results, we compared the present method with the Jaffe's colorimetric assay by measuring real urine samples. The method was reliable, sensitive, high-speed, low-cost and suitable for the routine analysis of creatinine in biofluids.
引用
收藏
页码:1287 / 1293
页数:7
相关论文
共 31 条
[1]   Analysis of creatine and creatinine in urine by capillary electrophoresis [J].
Burke, DG ;
MacLean, PG ;
Walker, RA ;
Dewar, PJ ;
Smith-Palmer, T .
JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (02) :479-485
[2]   Development of a fast capillary electrophoresis method for determination of creatinine in urine samples [J].
Costa, Ana Carolina O. ;
da Costa, Jose Luiz ;
Tonin, Fernando G. ;
Tavares, Marina F. M. ;
Micke, Gustavo Arnadeu .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1171 (1-2) :140-143
[3]   Certified reference materials (GBW09170 and 09171) of creatinine in human serum [J].
Dai, Xinhua ;
Fang, Xiang ;
Shao, Mingwu ;
Li, Ming ;
Huang, Zejian ;
Li, Hongmei ;
Jiang, You ;
Song, Dewei ;
He, Yajuan .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (5-6) :429-435
[4]   Determination of antitubercular drugs in urine and pharmaceuticals by LC using a gradient flow combined with programmed diode array photometric detection [J].
Espinosa-Mansilla, A ;
Acedo-Valenzuela, MI ;
de la Peña, AM ;
Cañada, FC ;
López, FS .
TALANTA, 2002, 58 (02) :273-280
[5]   Capillary electrophoretic determination of triamterene, methotrexate, and creatinine in human urine [J].
Flores, JR ;
Nevado, JJB ;
Merás, ID ;
Gómez, MJR .
JOURNAL OF SEPARATION SCIENCE, 2005, 28 (07) :658-664
[6]   Direct detection of renal function markers using microchip CE with pulsed electrochemical detection [J].
Garcia, CD ;
Henry, CS .
ANALYST, 2004, 129 (07) :579-584
[7]   Hadamard transform microchip electrophoresis combined with laser-induced fluorescence detection using a compact neodymium-doped yttrium aluminum garnet laser emitting at 532 nm [J].
Hata, Kazuki ;
Kaneta, Takashi ;
Imasaka, Totaro .
JOURNAL OF APPLIED PHYSICS, 2009, 105 (10)
[8]   Electrochemical sensor for measurement of urea and creatinine in serum based on ac impedance measurement of enzyme-catalyzed polymer transformation [J].
Ho, WO ;
Krause, S ;
McNeil, CJ ;
Pritchard, JA ;
Armstrong, RD ;
Athey, D ;
Rawson, K .
ANALYTICAL CHEMISTRY, 1999, 71 (10) :1940-1946
[9]   Towards microalbuminuria determination on a disposable diagnostic microchip with integrated fluorescence detection based on thin-film organic light emitting diodes [J].
Hofmann, O ;
Wang, XH ;
deMello, JC ;
Bradley, DDC ;
deMello, AJ .
LAB ON A CHIP, 2005, 5 (08) :863-868
[10]   Microchip capillary electrophoresis with electrochemical detector for precolumn enzymatic analysis of glucose, creatinine, uric acid and ascorbic acid in urine and serum [J].
Lee, HL ;
Chen, SC .
TALANTA, 2004, 64 (03) :750-757