Optimal design and techno-economic analysis of a hybrid solar-wind power generation system

被引:508
作者
Yang Hongxing [1 ]
Zhou Wei [1 ]
Lou Chengzhi [2 ]
机构
[1] Hong Kong Polytech Univ, Renewable Energy Res Grp, Hong Kong, Hong Kong, Peoples R China
[2] Tianjin Univ, Sch Environm Sci & Technol, Tianjin 300072, Peoples R China
关键词
Hybrid solar-wind system; LPSP; Annualized cost of system; Genetic algorithm; MODEL; BATTERIES; ARRAY;
D O I
10.1016/j.apenergy.2008.03.008
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Solar energy and wind energy are the two most viable renewable energy resources in the world. Good compensation characters are usually found between solar energy and wind energy. This paper recommend an optimal design model for designing hybrid solar-wind systems employing battery banks for calculating the system optimum configurations and ensuring that the annualized cost of the systems is minimized while satisfying the custom required loss of power supply probability (LPSP). The five decision variables included in the optimization process are the PV module number, PV module slope angle, wind turbine number, wind turbine installation height and battery capacity. The proposed method has been applied to design a hybrid system to Supply power for a telecommunication relay station along southeast coast of China. The research and project monitoring results of the hybrid project were reported, good complementary characteristics between the solar and wind energy were found, and the hybrid system turned out to be able to perform very well as expected throughout the year with the battery over-discharge situations seldom Occurred. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 11 条
[1]   Methodology for optimally sizing the combination of a battery bank and PV array in a Wind/PV hybrid system [J].
Borowy, BS ;
Salameh, ZM .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1996, 11 (02) :367-373
[2]   Dynamic battery model for photovoltaic applications [J].
Guasch, D ;
Silvestre, S .
PROGRESS IN PHOTOVOLTAICS, 2003, 11 (03) :193-206
[3]   Operation conditions of batteries in PV applications [J].
Jossen, A ;
Garche, J ;
Sauer, DU .
SOLAR ENERGY, 2004, 76 (06) :759-769
[4]   Lead acid batteries in solar refrigeration systems [J].
Kattakayam, TA ;
Srinivasan, K .
RENEWABLE ENERGY, 2004, 29 (08) :1243-1250
[5]   Field experience on solar electric power systems and their potential in Palestine [J].
Mahmoud, MM ;
Ibrik, IH .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2003, 7 (06) :531-543
[6]   Hybrid solar/wind power system probabilistic modelling for long-term performance assessment [J].
Tina, G ;
Gagliano, S ;
Raiti, S .
SOLAR ENERGY, 2006, 80 (05) :578-588
[7]   Long-term monitoring of photovoltaic devices [J].
van Dyk, EE ;
Meyer, EL ;
Vorster, FJ ;
Leitch, AWR .
RENEWABLE ENERGY, 2002, 25 (02) :183-197
[8]   A novel optimization sizing model for hybrid solar-wind power generation system [J].
Yang, Hongxing ;
Lu, Lin ;
Zhou, Wei .
SOLAR ENERGY, 2007, 81 (01) :76-84
[9]   Weather data and probability analysis of hybrid photovoltaic-wind power generation systems in Hong Kong [J].
Yang, HX ;
Lu, L ;
Burnett, J .
RENEWABLE ENERGY, 2003, 28 (11) :1813-1824
[10]  
Yang HX., 2004, ASHRAE T, V110, P424