Gadolinium-enhanced three-dimensional magnetic resonance angiography of pulmonary and systemic venous anomalies

被引:108
作者
Greil, GF
Powell, AJ
Gildein, HP
Geva, T
机构
[1] Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
[2] Childrens Hosp, Dept Radiol, Boston, MA 02115 USA
[3] Harvard Univ, Sch Med, Dept Pediat, Boston, MA USA
[4] Harvard Univ, Sch Med, Dept Radiol, Boston, MA USA
关键词
D O I
10.1016/S0735-1097(01)01730-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The goal of this study was to evaluate the diagnostic value of gadolinium (Gd)-enhanced three-dimensional (3D) magnetic resonance angiography (MRA) in patients with congenital and acquired anomalies of the pulmonary and systemic veins. BACKGROUND Gadolinium-enhanced 3D MRA is a fast magnetic resonance imaging technique that has shown great promise in the evaluation of large and medium-sized arteries. However, its application to venous anomalies has not been studied in detail. METHODS The study retrospectively analyzed all patients who under-went Cd-enhanced 3D MRA examination from January 1998 through January 2001, were diagnosed with anomalies of the pulmonary or systemic veins and had additional diagnostic data available for comparison with the MRA findings. RESULTS Sixty-one patients (age 1 day to 60 years) were included, Image acquisition was completed in 29 +/- 6.9 s. Pulmonary venous anomalies were found in 37 patients, systemic venous anomalies in 17 patients and both pulmonary and systemic venous anomalies in 7 patients. Compared with available diagnostic information by other modalities, all known or suspected venous anomalies were imaged by 3D MRA. In three patients, catheterization did not detect anomalies of the pulmonary veins that were subsequently diagnosed by MRA. The 3D MRA diagnoses were followed by 10 interventional catheterization procedures and 15 operations. In 74% of patients, 3D MRA either diagnosed previously unsuspected venous anomalies (28%) or added new clinically important information (46%). The mechanism of pulmonary vein compression in eight patients was determined by MRA, but not by other imaging modalities. Using a five-level grading system for MRA image quality (1 = nondiagnostic; 5 = excellent), the average grade was 4.6 +/- 0.6, with a 0.28 +/- 0.6 mean grade difference between two independent observers. CONCLUSIONS Gadolinium-enhanced 3D MRA is capable of rapidly and accurately, diagnosing a wide spectrum of pulmonary and systemic venous anomalies and is a useful noninvasive alternative to diagnostic catheterization. (C) 2002 by the American College of Cardiology.
引用
收藏
页码:335 / 341
页数:7
相关论文
共 30 条
[21]  
2-Z
[22]   EVALUATION OF INFRADIAPHRAGMATIC TOTAL ANOMALOUS PULMONARY VENOUS CONNECTION WITH TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
SNIDER, AR ;
SILVERMAN, NH ;
TURLEY, K ;
EBERT, PA .
CIRCULATION, 1982, 66 (05) :1129-1132
[23]  
STUMPER O, 1991, BRIT HEART J, V66, P411
[24]   2-DIMENSIONAL ECHOCARDIOGRAPHY IN THE PREOPERATIVE AND POSTOPERATIVE MANAGEMENT OF TOTALLY ANOMALOUS PULMONARY VENOUS CONNECTION [J].
VANDERVELDE, ME ;
PARNESS, IA ;
COLAN, SD ;
SPEVAK, PJ ;
LOCK, JE ;
MAYER, JE ;
SANDERS, SP .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (07) :1746-1751
[25]  
VICK G, 2001, J CARDIOVASC MAGN R, V3, P149
[26]  
Vick GW, 2000, PEDIATR CARDIOL, V21, P27
[27]   Complications associated with pediatric cardiac catheterization [J].
Vitiello, R ;
McCrindle, BW ;
Nykanen, D ;
Freedom, RM ;
Benson, LN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (05) :1433-1440
[28]   Anomalies of pulmonary veins: Usefulness of spin-echo and gradient-echo MR images [J].
White, CS ;
Baffa, JM ;
Haney, PJ ;
Campbell, AB ;
NessAiver, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1365-1368
[29]   MR imaging of congenital anomalies of the thoracic veins [J].
White, CS ;
Baffa, JM ;
Haney, PJ ;
Pace, ME ;
Campbell, AB .
RADIOGRAPHICS, 1997, 17 (03) :595-608
[30]   Magnetic resonance angiography - Update on applications for extracranial arteries [J].
Yucel, EK ;
Anderson, CM ;
Edelman, RR ;
Grist, TM ;
Baum, RA ;
Manning, WJ ;
Culebras, A ;
Pearce, W .
CIRCULATION, 1999, 100 (22) :2284-2301