Perfusion MR imaging with FAIR true FISP spin labeling in patients with and without renal artery stenosis: Initial experience

被引:82
作者
Fenchel, M
Martirosian, P
Langanke, J
Giersch, J
Miller, S
Stauder, NI
Kramer, U
Claussen, CD
Schick, F
机构
[1] Univ Tubingen, Dept Diagnost Radiol, Sect Expt Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Internal Med, Div Nephrol, D-72076 Tubingen, Germany
关键词
D O I
10.1148/radiol.2382041623
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
me purpose of this study was to prospectively evaluate on arterial spin-labeling technique, flow-sensitive alternating inversion-recovery (FAIR) fast imaging with steady, state precession (FISP), for noninvasive quantification, of renal perfusion in patients without a history of renal artery stenosis (RAS) and in patients with proved RAS. The study was approved by the local ethics committee, and all participants provided written informed consent. Six patients with hypertension but no history of renal artery disease and 12 patients with RAS tinder-went FAIR true FISP magnetic resonance (MR) imaging in a whole-body 1.5-T unit. RAS grade and scintigraphic perfusion data served as reference standards. On the FAIR true FISP perfusion images, severe RAS (> 70% luminal narrowing) could be clearly, distinguished from no or mild RAS and moderate RAS (<= 70% luminal narrowing) (P <.005). Significant correlations between FAIR perfnsion data and stenosis grade (r = -0.76) and between FAIR and single photon emission computed tomographic perfusion values (r = 0.83) were observed. FAIR time FISP was found to be suitable, qnintitative perfusion imaging of the kidneys in patients with RAS. RSNA, 2006.
引用
收藏
页码:1013 / 1021
页数:9
相关论文
共 39 条
[1]  
Berr SS, 1999, J MAGN RESON IMAGING, V10, P886, DOI 10.1002/(SICI)1522-2586(199911)10:5<886::AID-JMRI38>3.0.CO
[2]  
2-P
[3]   Assessment of T1 and T*2 effects in vivo and ex vivo using iron oxide nanoparticles in steady state-dependence on blood volume and water exchange [J].
Bjornerud, A ;
Johansson, LO ;
Briley-Sæbo, K ;
Ahlström, HK .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) :461-471
[4]   Contrast agent-associated nephrotoxicity [J].
Briguori, C ;
Tavano, D ;
Colombo, A .
PROGRESS IN CARDIOVASCULAR DISEASES, 2003, 45 (06) :493-503
[5]  
BUBECK B, 1990, J NUCL MED, V31, P1285
[6]  
Calamante F, 1996, NMR BIOMED, V9, P277
[7]  
Calamante F, 1996, NMR BIOMED, V9, P79, DOI 10.1002/(SICI)1099-1492(199604)9:2<79::AID-NBM399>3.0.CO
[8]  
2-4
[9]   STAR-HASTE: Perfusion imaging without magnetic susceptibility artifact [J].
Chen, Q ;
Siewert, B ;
Bly, BM ;
Warach, S ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :404-408
[10]   NEWER TESTS FOR THE DIAGNOSIS OF RENOVASCULAR DISEASE [J].
DAVIDSON, RA ;
WILCOX, CS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 268 (23) :3353-3358