STAR-HASTE: Perfusion imaging without magnetic susceptibility artifact

被引:41
作者
Chen, Q
Siewert, B
Bly, BM
Warach, S
Edelman, RR
机构
[1] BETH ISRAEL DEACONESS MED CTR,DEPT RADIOL,MRI,BOSTON,MA 02215
[2] BETH ISRAEL DEACONESS MED CTR,DEPT NEUROL,BOSTON,MA 02215
[3] HARVARD UNIV,SCH MED,BOSTON,MA
关键词
magnetic resonance imaging; perfusion imaging; magnetic susceptibility artifact;
D O I
10.1002/mrm.1910380308
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A novel magnetic resonance imaging technique (STAR-HASTE) based on pulsed arterial spin labeling using a single shot acquisition method is described for perfusion imaging. The method is similar to EPISTAR in using STAR (Signal Targeting with Alternating Radiofrequency) technique for pulsed radiofrequency labeling of inflowing blood, but uses a half-Fourier single shot turbo spin-echo (HASTE) sequence for data acquisition instead of echo-planar imaging (EPI). Our preliminary studies show that STAR-HASTE permits perfusion imaging to be performed without many of the artifacts encountered with other imaging methods based on EPI acquisition. The novel method not only provides similar perfusion information to that obtained by EPISTAR, as demonstrated in the functional brain imaging study, but also eliminates magnetic susceptibility artifacts and image distortion commonly observed in EPI images. Furthermore, this technique can be readily implemented in MR systems without EPI capability.
引用
收藏
页码:404 / 408
页数:5
相关论文
共 19 条
[1]   TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION [J].
BANDETTINI, PA ;
WONG, EC ;
HINKS, RS ;
TIKOFSKY, RS ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) :390-397
[2]   FUNCTIONAL NMR IMAGING USING FAST SPIN-ECHO AT 1.5 T [J].
CONSTABLE, RT ;
KENNAN, RP ;
PUCE, A ;
MCCARTHY, G ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :686-690
[3]   THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI [J].
CONSTABLE, RT ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :9-24
[4]  
CONSTABLE RT, 1992, MAGN RESON IMAGING, V25, P390
[5]   QUALITATIVE MAPPING OF CEREBRAL BLOOD-FLOW AND FUNCTIONAL LOCALIZATION WITH ECHO-PLANAR MR-IMAGING AND SIGNAL TARGETING WITH ALTERNATING RADIO-FREQUENCY [J].
EDELMAN, RR ;
SIEWERT, B ;
DARBY, DG ;
THANGARAJ, V ;
NOBRE, AC ;
MESULAM, MM ;
WARACH, S .
RADIOLOGY, 1994, 192 (02) :513-520
[6]   DYNAMIC MR IMAGING OF HUMAN BRAIN OXYGENATION DURING REST AND PHOTIC-STIMULATION [J].
FRAHM, J ;
BRUHN, H ;
MERBOLDT, KD ;
HANICKE, W .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (05) :501-505
[7]   ARTIFACTS DUE TO STIMULUS CORRELATED MOTION IN FUNCTIONAL IMAGING OF THE BRAIN [J].
HAJNAL, JV ;
MYERS, R ;
OATRIDGE, A ;
SCHWIESO, JE ;
YOUNG, IR ;
BYDDER, GM .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (03) :283-291
[8]   CLINICAL-APPLICATIONS AND METHODOLOGICAL DEVELOPMENTS OF THE RARE TECHNIQUE [J].
HENNIG, J ;
FRIEDBURG, H .
MAGNETIC RESONANCE IMAGING, 1988, 6 (04) :391-395
[9]   GRADIENT MOMENT NULLING IN FAST SPIN-ECHO [J].
HINKS, RS ;
CONSTABLE, RT .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (06) :698-706
[10]  
Kiefer B., 1994, J MAGN RESON IMAGING, V4, P86