The fast spin echo sequence combines data from many echo signals in a Carr-Purcell-Meiboom-Gill echo train to form a single image. Much of the signal in the second and later echoes results from the coherent addition of stimulated echo signal components back to the spin echo signal. Because stimulated echoes experience no dephasing effects during the time that they are stored as M(z) magnetization, they experience a different gradient first moment than does the spin echo. This leads to flow-related phase differences between different echo components and results in flow voids and ghosting, even when the first moment is nulled for the spin echo signal. A method of gradient moment nulling that correctly compensates both spin echo and stimulated echo components has been developed. The simplest solution involves nulling the first gradient moment at least at the RF pulses and preferably at both the RF pulses and the echoes. Phantom and volunteer studies demonstrate good suppression of flow-related artifacts.
引用
收藏
页码:698 / 706
页数:9
相关论文
共 20 条
[1]   SIGNAL-TO-NOISE AND CONTRAST IN FAST SPIN-ECHO (FSE) AND INVERSION RECOVERY FSE IMAGING [J].
CONSTABLE, RT ;
SMITH, RC ;
GORE, JC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (01) :41-47
[2]   ERRORS IN T2 ESTIMATION USING MULTISLICE MULTIPLE-ECHO IMAGING [J].
CRAWLEY, AP ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (01) :34-47
[3]   MULTIECHO MULTIMOMENT REFOCUSING OF MOTION IN MAGNETIC-RESONANCE-IMAGING - MEM-MO-RE [J].
DUERK, JL ;
SIMONETTI, OP ;
HURST, GC ;
MOTTA, AO .
MAGNETIC RESONANCE IMAGING, 1990, 8 (05) :535-541
[4]   THEORETICAL ASPECTS OF MOTION SENSITIVITY AND COMPENSATION IN ECHO-PLANAR IMAGING [J].
DUERK, JL ;
SIMONETTI, OP .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06) :643-650
[5]   ANALYSIS OF IMAGING AXES SIGNIFICANCE IN MOTION ARTIFACT SUPPRESSION TECHNIQUE (MAST) - MRI OF TURBULENT-FLOW AND MOTION [J].
DUERK, JL ;
PATTANY, PM .
MAGNETIC RESONANCE IMAGING, 1989, 7 (03) :251-263
[6]  
HAAKE EM, 1987, AM J ROENTGENOL, V148, P1251
[7]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833
[8]   CLINICAL-APPLICATIONS AND METHODOLOGICAL DEVELOPMENTS OF THE RARE TECHNIQUE [J].
HENNIG, J ;
FRIEDBURG, H .
MAGNETIC RESONANCE IMAGING, 1988, 6 (04) :391-395
[9]   MULTIECHO IMAGING SEQUENCES WITH LOW REFOCUSING FLIP ANGLES [J].
HENNIG, J .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03) :397-407
[10]   EVEN-ECHO REPHASING AND CONSTANT VELOCITY FLOW [J].
KATZ, J ;
PESHOCK, RM ;
MALLOY, CR ;
SCHAEFER, S ;
PARKEY, RW .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (05) :422-430