Dioxin abatement strategies and mass balance at a municipal waste management plant

被引:75
作者
Abad, E [1 ]
Adrados, MA [1 ]
Caixach, J [1 ]
Rivera, J [1 ]
机构
[1] CSIC, IIQAB, Mass Spectrometry Lab, Dept Ecotechnol, Barcelona 08034, Spain
关键词
D O I
10.1021/es010039j
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Since the thermal management of municipal solid waste (MSW) is considered to be one of the major sources of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs), the purpose of this study was to show the results of a dioxin abatement program performed in the municipal waste incineration (MWI) plant of Tarragona (NE Spain). Previously, stack gas emission levels of PCDDs/PCDFs around 3.26 ng I-TEQ/Nm(3) were determined when the gas-cleaning system consisted only of an electrostatic precipitator (ESP). Decreased levels, below 0.1 ng I-TEQ/Nm(3), were observed when a new air pollution control system was installed. This new system was improved by the injection of activated carbon, which helped to lower the levels of PCDDs/PCDFs to around 0.01 ng I-TEG/Nm(3). Considering the absence of a particular impact on herbages soils, and ambient air around the plant, as reported in previous works, and the hypothesis that a modern installation could become a sink for dioxins instead of a source, a dioxin mass balance was evaluated. The study compared in a large-scale MWI plant the levels of PCDDs/PCDFs of all input and output contributors (MSW, ambient air, stack gas emission, fly ash, and slag) forming part of the inventory collected in various monitoring campaigns. The findings revealed a remarkable homogeneity in output values (between 1.19 and 2.62 ng I-TEQ/yr) in contrast to the large variability observed in input values. In the first sampling campaign, the dioxin content in MSW was around 64.15 ng I-TEQ/kg, and a negative balance, of 7.68 g I-TEQ/yr was Calculated. However, in the latest campaign, levels were about 2.36 ng I-TEG/kg MSW, resulting in a positive balance of 2.28 g I-TEG/yr.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 42 条
[1]   Application of DB-5ms gas chromatography column for the complete assignment of 2,3,7,8-substituted polychlorodibenzo-p-dioxins and polychlorodibenzofurans in samples from municipal waste incinerator emissions [J].
Abad, E ;
Caixach, J ;
Rivera, J .
JOURNAL OF CHROMATOGRAPHY A, 1997, 786 (01) :125-134
[2]   PCDD/PCDF from emission sources and ambient air in northeast Spain [J].
Abad, E ;
Caixach, J ;
Rivera, J .
CHEMOSPHERE, 1997, 35 (03) :453-463
[3]   Evaluation of a new automated cleanup system for the analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans in environmental samples [J].
Abad, E ;
Sauló, J ;
Caixach, J ;
Rivera, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 893 (02) :383-391
[4]   Dioxin mass balance in a municipal waste incinerator [J].
Abad, E ;
Adrados, MA ;
Caixach, J ;
Fabrellas, B ;
Rivera, J .
CHEMOSPHERE, 2000, 40 (9-11) :1143-1147
[5]   Dioxins in the environment: A review of trend data [J].
Alcock, RE ;
Jones, KC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (11) :3133-3143
[6]  
CARLSSON K, 1994, ORGANOHALOGEN COMPD, V19, P365
[7]   STUDY OF POLYCHLORINATED DIBENZODIOXINS AND FURANS FROM MUNICIPAL WASTE INCINERATOR EMISSIONS IN THE NETHERLANDS - ANALYTICAL METHODS AND LEVELS IN THE ENVIRONMENT AND HUMAN FOOD-CHAIN [J].
DEJONG, APJM ;
LIEM, AKD ;
HOOGERBRUGGE, R .
JOURNAL OF CHROMATOGRAPHY, 1993, 643 (1-2) :91-106
[8]   DENOVO-SYNTHESIS OF CHLORINATED BIPHENYLS, DIBENZOFURANS AND DIBENZO-PARA-DIOXINS IN THE FLY-ASH CATALYZED REACTION OF TOLUENE WITH HYDROCHLORIC-ACID [J].
DELEER, EWB ;
LEXMOND, RJ ;
DEZEEUW, MA .
CHEMOSPHERE, 1989, 19 (8-9) :1141-1152
[9]  
DOMINGO JL, 1999, ORGANOHALOGEN COMPDS, V41, P149
[10]  
*EPA, 1995, 1613 EPA