Charge transfer through DNA: A selective electrochemical DNA biosensor

被引:167
作者
Wong, ELS [1 ]
Gooding, JJ [1 ]
机构
[1] Univ New S Wales, Sch Chem, Sydney, NSW 2052, Australia
关键词
D O I
10.1021/ac0509096
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The charge-transfer properties of DNA duplexes are exploited to produce a fast, simple, sensitive, and selective DNA biosensor by exposing the DNA recognition interface to a sample containing target DNA and the redox-active intercalator, anthraquinonemonosulfonic acid (AQMS). Electrochemistry from electron transfer through the DNA to AQMS intercalated into DNA duplexes can be differentiated from electrochemistry due to direct access of the AQMS to the electrode surface due to the difference in the environment of the AQMS giving a shift in the potential at which the molecule is reduced. The ability to distinguish between the two electrochemical signals enables DNA hybridization to be monitored in real time. This in situ detection scheme has good selectivity, being able to differentiate between a complementary target DNA sequence and one containing either C-A or G-A singlebase mismatches. The concentration detection limit of the biosensor is 0.5 nM (1 pmol) with an assay time of 1 h. The fact that the end user is only required to simultaneously add the sample containing the target DNA and AQMS gives a DNA biosensor that is highly compatible with PCR on chip technologies.
引用
收藏
页码:2138 / 2144
页数:7
相关论文
共 37 条
[11]   Single-base mismatch detection based on charge transduction through DNA [J].
Kelley, SO ;
Boon, EM ;
Barton, JK ;
Jackson, NM ;
Hill, MG .
NUCLEIC ACIDS RESEARCH, 1999, 27 (24) :4830-4837
[12]   Electrochemistry of methylene blue bound to a DNA-modified electrode [J].
Kelley, SO ;
Barton, JK ;
Jackson, NM ;
Hill, MG .
BIOCONJUGATE CHEMISTRY, 1997, 8 (01) :31-37
[13]  
Kelley SO, 1999, ANGEW CHEM INT EDIT, V38, P941, DOI 10.1002/(SICI)1521-3773(19990401)38:7<941::AID-ANIE941>3.0.CO
[14]  
2-7
[15]   Molecular beacons - Spectral genotyping of human alleles [J].
Kostrikis, LG ;
Tyagi, S ;
Mhlanga, MM ;
Ho, DD ;
Kramer, FR .
SCIENCE, 1998, 279 (5354) :1228-1229
[16]   A fiber-optic evanescent wave DNA biosensor based on novel molecular beacons [J].
Liu, XJ ;
Tan, WH .
ANALYTICAL CHEMISTRY, 1999, 71 (22) :5054-5059
[17]   SEQUENCE-SELECTIVE BIOSENSOR FOR DNA-BASED ON ELECTROACTIVE HYBRIDIZATION INDICATORS [J].
MILLAN, KM ;
MIKKELSEN, SR .
ANALYTICAL CHEMISTRY, 1993, 65 (17) :2317-2323
[18]  
Niemeyer CM, 1999, ANGEW CHEM INT EDIT, V38, P2865, DOI 10.1002/(SICI)1521-3773(19991004)38:19<2865::AID-ANIE2865>3.0.CO
[19]  
2-F
[20]   REAL-TIME MONITORING OF DNA MANIPULATIONS USING BIOSENSOR TECHNOLOGY [J].
NILSSON, P ;
PERSSON, B ;
UHLEN, M ;
NYGREN, PA .
ANALYTICAL BIOCHEMISTRY, 1995, 224 (01) :400-408