Wear in alumina-on-alumina ceramic total hip replacements A RETRIEVAL ANALYSIS OF EDGE LOADING

被引:57
作者
Esposito, C. I. [1 ]
Walter, W. L. [1 ]
Roques, A. [1 ]
Tuke, M. A. [1 ]
Zicat, B. A. [1 ]
Walsh, W. R. [1 ]
Walter, K. [1 ]
机构
[1] Specialist Orthopaed Grp, Sydney, NSW, Australia
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2012年 / 94B卷 / 07期
关键词
ACETABULAR COMPONENT; JOINT REPLACEMENTS; POLYETHYLENE WEAR; ARTHROPLASTY; BEARINGS; ORIENTATION; PROSTHESES; SQUEAKING; DEBRIS; INCLINATION;
D O I
10.1302/0301-620X.94B7.29115
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
We analysed 54 alumina ceramic-on-ceramic bearings from total hip replacements retrieved at one centre after a mean duration of 3.5 years (0.2 to 10.6) in situ. These implants were obtained from 54 patients (16 men and 38 women) with a mean age of 67 years (33 to 88) who underwent revision for a variety of reasons. Posterior edge loading was found in the majority of these retrievals (32 out of 54). Anterosuperior edge loading occurred less often but produced a higher rate of wear. Stripe wear on the femoral heads had a median volumetric wear rate of 0.2 mm(3)/year (0 to 7.2). The wear volume on the femoral heads corresponded to the width of edge wear on the matching liner. Anteversion of the acetabular component was found to be a more important determinant than inclination for wear in ceramic bearings. Posterior edge loading may be considered to be a normal occurrence in ceramic-on-ceramic bearings, with minimal clinical consequences. Edge loading should be defined as either anterosuperior or posterior, as each edge loading mechanism may result in different clinical implications.
引用
收藏
页码:901 / 907
页数:7
相关论文
共 34 条
[1]
Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[2]
Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
[3]
THE USE OF DENSE ALUMINA ALUMINA CERAMIC COMBINATION IN TOTAL HIP-REPLACEMENT [J].
BOUTIN, P ;
CHRISTEL, P ;
DORLOT, JM ;
MEUNIER, A ;
DEROQUANCOURT, A ;
BLANQUAERT, D ;
HERMAN, S ;
SEDEL, L ;
WITVOET, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (12) :1203-1232
[4]
Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement [J].
De Haan, R. ;
Pattyn, C. ;
Gill, H. S. ;
Murray, D. W. ;
Campbell, P. A. ;
De Smet, K. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (10) :1291-1297
[5]
Bioengineering reasons for the failure of metal-on-metal hip prostheses AN ENGINEER'S PERSPECTIVE [J].
Fisher, J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (08) :1001-1004
[6]
The In Vivo Linear and Volumetric Wear of Hip Resurfacing Implants Revised for Pseudotumor [J].
Glyn-Jones, Sion ;
Roques, Anne ;
Taylor, Adrian ;
Kwon, Young-Min ;
McLardy-Smith, Peter ;
Gill, Harinderjit S. ;
Walter, William ;
Tuke, Mike ;
Murray, David .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (23) :2180-2188
[7]
Alumina-alumina artificial hip joints. Part I: a histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision [J].
Hatton, A ;
Nevelos, JE ;
Nevelos, AA ;
Banks, RE ;
Fisher, J ;
Ingham, E .
BIOMATERIALS, 2002, 23 (16) :3429-3440
[8]
Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty [J].
Hui, AJ ;
McCalden, FW ;
Martell, JM ;
MacDonald, SJ ;
Bourne, RB ;
Rorabeck, CH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (03) :505-511
[9]
Isaac G H, 1996, Proc Inst Mech Eng H, V210, P209, DOI 10.1243/PIME_PROC_1996_210_414_02
[10]
Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus [J].
Jin, ZM ;
Dowson, D ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (03) :247-256