ADC mapping of the human optic nerve: Increased resolution, coverage, and reliability with CSF-suppressed ZOOM-EPI

被引:108
作者
Wheeler-Kingshott, CAM [1 ]
Parker, GJM [1 ]
Symms, MR [1 ]
Hickman, SJ [1 ]
Tofts, PS [1 ]
Miller, DH [1 ]
Barker, GJ [1 ]
机构
[1] UCL, Inst Neurol, Dept Clin Neurol, NMR Res Unit, London WC1N 3BG, England
关键词
optic nerve; diffusion; inner volume imaging; EPI; Rayleigh noise;
D O I
10.1002/mrm.10016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The mean apparent diffusion coefficient (ADC) of the human optic nerve (ON) has been quantified in vivo, and mean ADC maps are shown along the complete length of the nerve from the globe to the optic chiasm. The mean ADC, over the whole nerve, is shown to be 1058 x 10(-6) mm(2) s(-1) (standard deviation (SID), over nine 3-mm slices, 101 x 10(-6) mm(2) s(-1); range (833-1178) x 10(-6) mm(2) s(-1)). The robustness of the method relies on acquisition of high-resolution coronal images of the ON using the ZOOM-EPI technique, which makes use of a shortened echo train length for increased resolution with decreased susceptibility-induced distortions. Suppression of the cerebrospinal fluid (CSF) and fat signals from tissues that surround the ON also helps successful identification and delineation of the nerve. Averaging of magnitude images is used to compensate for the inherently low signal-to-noise ratio (SNR) of the acquired images; the effects of the Rayleigh distributed noise in such images are allowed for during ADC calculations. Magn Reson Med 47:24-31, 2002. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 43 条
[1]   RAPID LINE SCAN TECHNIQUE FOR ARTIFACT-FREE IMAGES OF MOVING-OBJECTS [J].
AILION, DC ;
GANESAN, K ;
CASE, TA ;
CHRISTMAN, RA .
MAGNETIC RESONANCE IMAGING, 1992, 10 (05) :747-754
[2]   Technical issues for the study of the optic nerve with MRI [J].
Barker, GJ .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 2000, 172 :S13-S16
[3]   MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
BIOPHYSICAL JOURNAL, 1994, 66 (01) :259-267
[4]   Consistent fat suppression with compensated spectral-spatial pulses [J].
Block, W ;
Pauly, J ;
Kerr, A ;
Nishimura, D .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) :198-206
[5]   MB-guided biopsy using a T2-weighted single-shot zoom imaging sequence (Local Look technique) [J].
Buecker, A ;
Adam, G ;
Neuerburg, JM ;
Glowinski, A ;
van Vaals, JJ ;
Guenther, RW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :955-959
[6]   Cerebral infarction: Time course of signal intensity changes on diffusion-weighted MR images [J].
Burdette, JH ;
Ricci, PE ;
Petitti, N ;
Elster, AD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (03) :791-795
[7]   INNER VOLUME MR IMAGING - TECHNICAL CONCEPTS AND THEIR APPLICATION [J].
FEINBERG, DA ;
HOENNINGER, JC ;
CROOKS, LE ;
KAUFMAN, L ;
WATTS, JC ;
ARAKAWA, M .
RADIOLOGY, 1985, 156 (03) :743-747
[8]  
Finsterbusch J, 1999, MAGNET RESON MED, V42, P772, DOI 10.1002/(SICI)1522-2594(199910)42:4<772::AID-MRM20>3.0.CO
[9]  
2-8
[10]  
FREEMAN AJ, 1998, P 6 ANN M ISMRM SYDN, P1265