The influence of signal noise on the accuracy of kinetic constants measured by surface plasmon resonance experiments

被引:21
作者
Ober, RJ
Ward, ES
机构
[1] Univ Texas, SW Med Ctr, Ctr Immunol, Dallas, TX 75235 USA
[2] Univ Texas, SW Med Ctr, Ctr Canc Immunobiol, Dallas, TX 75235 USA
[3] Univ Texas, Ctr Engn Math EC35, Richardson, TX 75083 USA
关键词
kinetic constants; surface plasmon resonance; BIAcore; Cramer Rao lower bound; signal averaging;
D O I
10.1006/abio.1999.4185
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An analysis is carried out to investigate the accuracy of kinetic parameters obtained using surface plasmon resonance methodology with a BIAcore instrument. The Cramer Rao lower bound for the least possible variance of an estimator of the kinetic parameters is determined. Using simulations it is shown that the standard least-squares estimation technique provides estimates that achieve this bound. The theoretical and simulation results are compared with experimental data obtained from an analysis of the interaction of the myc peptide with the anti-myc antibody, 9E10. This investigation indicates that the accuracy of the results depends on the signal level which has particular relevance to the design of experiments with low signal levels. It is shown how the accuracy of the estimates of the kinetic constants depends on the kinetic constants themselves and how the accuracy of the association constants depends on the concentration of the analyte that is used in the experiment. In addition, the effects of increasing the number of data points in the analysis of dissociation data on the accuracy of the estimates are quantitated. It is also demonstrated that signal averaging of data derived from repeat sensorgrams can result in a significant decrease in the standard deviation of the estimates. (C) 1999 Academic Press.
引用
收藏
页码:49 / 59
页数:11
相关论文
共 11 条
[1]  
[Anonymous], 1975, REPRINTING MONOGRAPH
[2]   ISOLATION OF MONOCLONAL-ANTIBODIES SPECIFIC FOR HUMAN C-MYC PROTO-ONCOGENE PRODUCT [J].
EVAN, GI ;
LEWIS, GK ;
RAMSAY, G ;
BISHOP, JM .
MOLECULAR AND CELLULAR BIOLOGY, 1985, 5 (12) :3610-3616
[3]   EFFECTS OF SOLUTE MULTIVALENCE ON THE EVALUATION OF BINDING CONSTANTS BY BIOSENSOR TECHNOLOGY - STUDIES WITH CONCANAVALIN-A AND INTERLEUKIN-6 AS PARTITIONING PROTEINS [J].
KALININ, NL ;
WARD, LD ;
WINZOR, DJ .
ANALYTICAL BIOCHEMISTRY, 1995, 228 (02) :238-244
[4]  
Morton TA, 1998, METHOD ENZYMOL, V295, P268
[5]   Competition BIAcore for measuring true affinities: Large differences from values determined from binding kinetics [J].
Nieba, L ;
Krebber, A ;
Pluckthun, A .
ANALYTICAL BIOCHEMISTRY, 1996, 234 (02) :155-165
[6]   The choice of reference cell in the analysis of kinetic data using BIAcore [J].
Ober, RJ ;
Ward, ES .
ANALYTICAL BIOCHEMISTRY, 1999, 271 (01) :70-80
[7]   Interpretation of deviations from pseudo-first-order kinetic behavior in the characterization of ligand binding by biosensor technology [J].
OShannessy, DJ ;
Winzor, DJ .
ANALYTICAL BIOCHEMISTRY, 1996, 236 (02) :275-283
[8]   Global analysis of a macromolecular interaction measured on BIAcore [J].
Roden, LD ;
Myszka, DG .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1996, 225 (03) :1073-1077
[9]   Kinetics of ligand binding to receptor immobilized in a polymer matrix, as detected with an evanescent wave biosensor .1. A computer simulation of the influence of mass transport [J].
Schuck, P .
BIOPHYSICAL JOURNAL, 1996, 70 (03) :1230-1249
[10]   Analysis of mass transport-limited binding kinetics in evanescent wave biosensors [J].
Schuck, P ;
Minton, AP .