A high-frequency continuous-wave Doppler ultrasound system for the detection of blood flow in the microcirculation

被引:46
作者
Christopher, DA
Burns, PN
Armstrong, J
Foster, FS
机构
[1] UNIV TORONTO,SUNNYBROOK HLTH SCI CTR,DEPT MED BIOPHYS,TORONTO,ON M4N 3M5,CANADA
[2] UNIV TORONTO,DEPT BIOMED ENGN,TORONTO,ON,CANADA
关键词
Doppler ultrasound; continuous-wave Doppler; high-frequency ultrasound; microcirculation; blood velocity measurement; duplex Doppler; ultrasonics;
D O I
10.1016/S0301-5629(96)00153-6
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Basic ultrasound physics and several clinical and experimental observations suggest that high-frequency Doppler ultrasound (HFD) operating in the frequency range 20-100 MHz holds the promise of detecting blood flow in the microcirculation. This article describes a directional, continuous-wave (CW), 1- to 200-MHz Doppler ultrasound system. The system electronics have a dynamic range of 100 dB, a noise floor of 10 nV and a directional isolation of 50 dB. The development of a 40-MHz Doppler transducer composed of two, 81-mu m-thick, lithium niobate crystals that have been air-backed and transmission-line tuned for maximum sensitivity is described. This device is used to test the CW Doppler system using string and capillary phantoms and in vivo tissue. We show that HFD can detect and measure velocities on the order of the blood velocities found in the capillaries (1 mm/s) and arterioles (5 mm/s) with suitable velocity (50-500 mu m/s) and temporal (20-250 ms) resolutions. In vivo measurements demonstrate that HFD is sensitive to the detection of blood flow in small vessels. Copyright (C) 1996 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1191 / 1203
页数:13
相关论文
共 26 条
[1]   ULTRASONIC ESTIMATION OF TISSUE PERFUSION - A STOCHASTIC APPROACH [J].
ADLER, RS ;
RUBIN, JM ;
FOWLKES, JB ;
CARSON, PL ;
PALLISTER, JE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (04) :493-500
[2]  
*AIUM STAND COMM, 1993, PERF CRIT MEAS DOPPL
[3]  
[Anonymous], 1995, ULTRASOUND BIOMICROS
[4]  
[Anonymous], [No title captured]
[5]  
ATKINSON P, 1982, DOPPLER ULTRASOUND I
[6]   VERY HIGH-FREQUENCY PULSED DOPPLER APPARATUS [J].
BERSON, M ;
PATAT, F ;
WANG, ZQ ;
BESSE, D ;
POURCELOT, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (02) :121-131
[7]  
BURNS PN, 1994, IEEE ULTRASONICS S P, V3, P1547
[8]   DESIGN FOR AN ULTRASOUND-BASED INSTRUMENT FOR MEASUREMENT OF TISSUE BLOOD-FLOW [J].
BURNS, SM ;
REID, MH .
BIOMATERIALS ARTIFICIAL CELLS AND ARTIFICIAL ORGANS, 1989, 17 (01) :61-68
[9]   THE EFFECT OF REFRACTION AND ASSUMED SPEEDS OF SOUND IN TISSUE AND BLOOD ON DOPPLER ULTRASOUND BLOOD VELOCITY-MEASUREMENTS [J].
CHRISTOPHER, DA ;
BURNS, PN ;
HUNT, JW ;
FOSTER, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (02) :187-201
[10]  
CHRISTOPHER DA, IN PRESS ULTRASOUND