Improved methods for image registration

被引:85
作者
Alpert, NM
Berdichevsky, D
Levin, Z
Morris, ED
Fischman, AJ
机构
[1] Division of Nuclear Medicine, Massachusetts General Hospital, Boston, MA 02114, Fruit Street
[2] PET Imaging Laboratory, Massachusetts General Hospital, Boston
关键词
D O I
10.1006/nimg.1996.0002
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We report a system for PET-MRI registration that is improved or optimized in several areas: (1) Automatic scalp/brain segmentation replaces manual drawing operations, (2) a new fast and accurate method of image registration, (3) visual assessment of registration quality is enhanced by composite imaging methods (i.e., fusion) and (4) the entire procedure is embedded in a commercially available scientific visualization package, thereby providing a consistent graphical user interface. The segmentation algorithm was tested on 17 MRI data sets and was successful in all cases. Accuracy of image registration was equal to that of the Woods algorithm, but 10 times faster for PET-PET and 4 times faster for PET-MRI. The image fusion method allows detection of misalignments on the order of 2-3 mm. These results demonstrate an integrated system for intermodality image registration, which is important because the procedure can be performed by technicians with no anatomic knowledge and reduces the required time from hours to about 15 min on a modern computer workstation. (C) 1996 Academic Press, Inc.
引用
收藏
页码:10 / 18
页数:9
相关论文
共 16 条
[1]   CONTOUR EXTRACTION PROBLEM WITH BIOMEDICAL APPLICATIONS [J].
ASHKAR, GP ;
MODESTINO, JW .
COMPUTER GRAPHICS AND IMAGE PROCESSING, 1978, 7 (03) :331-355
[2]   AN ACTIVE CONTOUR MODEL FOR MAPPING THE CORTEX [J].
DAVATZIKOS, CA ;
PRINCE, JL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (01) :65-80
[3]   BOUNDARY DETECTION BY CONSTRAINED OPTIMIZATION [J].
GEMAN, D ;
GEMAN, S ;
GRAFFIGNE, C ;
DONG, P .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (07) :609-628
[4]  
Haralick RM, 1981, REAL TIME PARALLEL C
[5]  
HARALICK RM, 1992, COMPUTER ROBOT VISIO, V1, pCH2
[6]   SNAKES - ACTIVE CONTOUR MODELS [J].
KASS, M ;
WITKIN, A ;
TERZOPOULOS, D .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1987, 1 (04) :321-331
[7]   PERFORMANCE-CHARACTERISTICS OF AN 8-RING WHOLE-BODY PET SCANNER [J].
KOPS, ER ;
HERZOG, H ;
SCHMID, A ;
HOLTE, S ;
FEINENDEGEN, LE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (03) :437-445
[8]  
Maurer C.R., 1993, Interactive Image-Guided Neurosurgery, V1, P17
[9]  
MORRIS ED, 1993, P SOC PHOTO-OPT INS, V1898, P146, DOI 10.1117/12.154499
[10]   ACCURATE 3-DIMENSIONAL REGISTRATION OF CT, PET, AND OR MR IMAGES OF THE BRAIN [J].
PELIZZARI, CA ;
CHEN, GTY ;
SPELBRING, DR ;
WEICHSELBAUM, RR ;
CHEN, CT .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (01) :20-26