Anti-heparin/platelet factor 4 antibody optical density values and the confirmatory procedure in the diagnosis of heparin-induced thrombocytopenia

被引:65
作者
Whitlatch, Nicole L. [1 ]
Perry, Stephanie L. [1 ]
Ortel, Thomas L. [1 ,2 ]
机构
[1] Duke Univ, Med Ctr, Dept Med, Div Hematol, Durham, NC 27706 USA
[2] Duke Univ, Med Ctr, Dept Pathol, Durham, NC 27706 USA
关键词
Heparins; platelet factor 4; heparin-induced thrombocytopenia;
D O I
10.1160/TH08-02-0118
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Laboratory testing for heparin-induced thrombocytopenia (HIT) includes the highly sensitive, though less specific, heparin/ platelet factor 4 (PF4) ELISA.A confirmatory test with excess heparin is routinely performed on positive ELISA results to improve test specificity; the significance of a negative confirmatory result is unknown. The aim was firstly to evaluate the clinical utility of the PF4 ELISA confirmatory assay, secondly to examine the relationship between ELISA optical density (OD) value and clinical diagnosis of HIT, and thirdly to assess current practice at a tertiary care medical centre regarding patients with anti-heparin/PF4 antibodies. Patients with anti-heparin/PF4 antibodies detected by commercial ELISA during 2005 were identified.A confirmatory test was performed on positive ELISA results. Patients were labeled confirmatory positive (confirm+) or confirmatory negative (confirm-). Patients were classified as HIT+ (met criteria for HIT), HIT? (HIT possible), and HIT- (did not meet criteria for HIT) utilizing ACCP guidelines. One hundred fifteen patients with anti-heparin/PF4 antibodies were identified. Ninetyeight patients were confirm+; 17 were confirm-.The majority of confirm+ patients were HIT+ or HIT?(72%);the majority of confirm- patients were HIT-(81%). Patients who were HIT+/confirm+ had higher ELISA OD values than patients who were HIT?/confirm+ or HIT-/confirm+ (p=0.031, p=0.001).Two confirm- patients were HIT+, one was HIT?; all had high ELISA OD values.Although confirm+ status correlated with clinical HITthe confirmatory procedure misclassified some patients by yielding a confirm- result despite clinical HIT with high ELISA OD values. Future studies should compare higher ELISA OD values with the confirmatory procedure as strategies to improve ELISA diagnostic specificity for HIT
引用
收藏
页码:678 / 684
页数:7
相关论文
共 16 条
[11]   No significant improvement in diagnostic specificity of an anti-PF4/polyanion immunoassay with use of high heparin confirmatory procedure [J].
Warkentin, TE ;
Sheppard, JI .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2006, 4 (01) :281-282
[12]   Laboratory testing for the antibodies that cause heparin-induced thrombocytopenia: How much class do we need? [J].
Warkentin, TE ;
Sheppard, JAI ;
Moore, JC ;
Moore, KM ;
Sigouin, CS ;
Kelton, JG .
JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 2005, 146 (06) :341-346
[13]  
Warkentin TE, 1999, THROMB HAEMOSTASIS, V82, P439
[14]   Heparin-induced thrombocytopenia and cardiac surgery (vol 76, pg 638, 2003) [J].
Warkentin, TE ;
Greinacher, A .
ANNALS OF THORACIC SURGERY, 2003, 76 (06) :2121-2131
[15]   A 14-year study of heparin-induced thrombocytopenia [J].
Warkentin, TE ;
Kelton, JG .
AMERICAN JOURNAL OF MEDICINE, 1996, 101 (05) :502-507
[16]   Thrombosis and ELISA optical density values in hospitalized patients with heparin-induced thrombocytopenia [J].
Zwicker, JI ;
Uhl, L ;
Huang, WY ;
Shaz, BH ;
Bauer, KA .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2004, 2 (12) :2133-2137