OBJECTIVE. The study purpose was to examine the usefulness of perfusion echoplanar MR imaging with a superparamagnetic iron oxide (SHU-555A) for evaluating the vascularity of hepatocellular carcinomas. SUBJECTS AND METHODS. Twenty-two patients with 32 hepatocellular carcinomas underwent perfusion imaging with bolus injection (0.7-1.1 ml) of SHU-555A. Echoplanar sequences included multishot spin-echo (17 patients) and single-shot gradient-echo (five patients) imaging. Image acquisition was repeated every 30 sec for 3 min with the multishot spin-echo sequence and every 2 sec for 100 sec with the single-shot gradient-echo sequence. Lesion signal intensity versus time curves were created for quantitative analysis. RESULTS. Transient decreases in tumor signal intensity (28.8% with multishot spin-echo and 63.3% with the single-shot gradient-echo) were seen in the perfusion phase. These decreases in signal intensity were statistically significantly (p <.01) different for each histologic type of hepatocellular carcinoma (poorly differentiated, 43.3%; well differentiated, 18.4%; and moderately differentiated, 24.8%). After the perfusion phase, the tumor signal intensities rapidly recovered. The multishot spin-echo sequence could detect some signal changes even in lesions smaller than 1 cm. CONCLUSION. Hepatocellular carcinoma vascularity can be evaluated with perfusion echoplanar imaging with SHU-555A. Because of its excellent temporal resolution, the single-shot gradient-echo echoplanar sequence detects the transient signal decrease in most lesions. The high image quality of the multishot spin-echo echoplanar sequence allows evaluation of the vascularity of even very small lesions.
引用
收藏
页码:207 / 213
页数:7
相关论文
共 29 条
[1]   LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING [J].
BELLIN, MF ;
ZAIM, S ;
AUBERTON, E ;
SARFATI, G ;
DURON, JJ ;
KHAYAT, D ;
GRELLET, J .
RADIOLOGY, 1994, 193 (03) :657-663
[2]   FUNCTIONAL CEREBRAL IMAGING BY SUSCEPTIBILITY-CONTRAST NMR [J].
BELLIVEAU, JW ;
ROSEN, BR ;
KANTOR, HL ;
RZEDZIAN, RR ;
KENNEDY, DN ;
MCKINSTRY, RC ;
VEVEA, JM ;
COHEN, MS ;
PYKETT, IL ;
BRADY, TJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (03) :538-546
[3]   HEPATIC TUMORS - DETECTION AND CHARACTERIZATION AT 1-T MR-IMAGING ENHANCED WITH AMI-25 [J].
DENYS, A ;
ARRIVE, L ;
SERVOIS, V ;
DUBRAY, B ;
NAJMARK, D ;
SIBERT, A ;
MENU, Y .
RADIOLOGY, 1994, 193 (03) :665-669
[4]   SUPERPARAMAGNETIC IRON-OXIDE - DETECTION OF FOCAL LIVER-LESIONS AT HIGH-FIELD-STRENGTH MR-IMAGING [J].
DUDA, SH ;
LANIADO, M ;
KOPP, AF ;
GRONEWALLER, E ;
AICHER, KP ;
PAVONE, P ;
JEHLE, E ;
CLAUSSEN, CD .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) :309-314
[5]   CONTRAST-ENHANCED ECHO-PLANAR MR-IMAGING OF MYOCARDIAL PERFUSION - PRELIMINARY-STUDY IN HUMANS [J].
EDELMAN, RR ;
LI, W .
RADIOLOGY, 1994, 190 (03) :771-777
[6]   CEREBRAL BLOOD-FLOW - ASSESSMENT WITH DYNAMIC CONTRAST-ENHANCED T2-STAR-WEIGHTED MR IMAGING AT 1.5-T [J].
EDELMAN, RR ;
MATTLE, HP ;
ATKINSON, DJ ;
HILL, T ;
FINN, JP ;
MAYMAN, C ;
RONTHAL, M ;
HOOGEWOUD, HM ;
KLEEFIELD, J .
RADIOLOGY, 1990, 176 (01) :211-220
[7]   SUPERPARAMAGNETIC IRON OXIDE-ENHANCED MR IMAGING - PULSE SEQUENCE OPTIMIZATION FOR DETECTION OF LIVER-CANCER [J].
FRETZ, CJ ;
ELIZONDO, G ;
WEISSLEDER, R ;
HAHN, PF ;
STARK, DD ;
FERRUCCI, JT .
RADIOLOGY, 1989, 172 (02) :393-397
[8]   DETECTION OF HEPATIC METASTASES - COMPARISON OF CONTRAST-ENHANCED CT, UNENHANCED MR IMAGING, AND IRON-OXIDE ENHANCED MR IMAGING [J].
FRETZ, CJ ;
STARK, DD ;
METZ, CE ;
ELIZONDO, G ;
WEISSLEDER, R ;
SHEN, JH ;
WITTENBERG, J ;
SIMEONE, J ;
FERRUCCI, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (04) :763-770
[9]   ENHANCEMENT OF LIVER HEMANGIOMAS ON T1-WEIGHTED MR SE IMAGES BY SUPERPARAMAGNETIC IRON-OXIDE PARTICLES [J].
GRANGIER, C ;
TOURNIAIRE, J ;
MENTHA, G ;
SCHIAU, R ;
HOWARTH, N ;
CHACHUAT, A ;
GROSSHOLZ, M ;
TERRIER, F .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (06) :888-896
[10]   CLINICAL-APPLICATION OF SUPERPARAMAGNETIC IRON-OXIDE TO MR IMAGING OF TISSUE PERFUSION IN VASCULAR LIVER-TUMORS [J].
HAHN, PF ;
STARK, DD ;
WEISSLEDER, R ;
ELIZONDO, G ;
SAINI, S ;
FERRUCCI, JT .
RADIOLOGY, 1990, 174 (02) :361-366