Vibration syndrome diagnosis using a cooling test verified by computerized photoplethysmography

被引:4
作者
Dyszkiewicz, A
Tendera, M
机构
[1] Univ Silesia, Dept Comp Sci, PL-41200 Sosnowiec, Poland
[2] L Warynski Silesian Med Acad, Div Cardiol 3, Katowice, Poland
关键词
vibration syndrome; computer cooling test diagnosis; micro circulation flow sensor modification; planimetric diagram estimation;
D O I
10.1088/0967-3334/27/4/003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study addresses the problem of vibration syndrome diagnosis by means of a cooling test verified by photoplethysmography. Measurement was taken on a small area on the fingertip plexus in which many arterio-venous anastomoses are present. In the opinion of many authors, flow disorders in this area are more typical for developing vibration syndrome than changes in the micro vessels. The study group comprised 128 subjects (58 women aged 40.9 +/- 5.4 years and 70 men aged 38.7 +/- 8.8 years) exposed to vibration. The control group consisted of 41 people (20 women aged 39.6 +/- 7.3 years and 21 men aged 39.3 +/- 6.4 years) who were not exposed to vibration. The patients were examined by a questionnaire and then a vibration perception threshold test and a cooling test were performed. The cooling test was verified both visually and using the computer method. Measurement data (S1, S2 and A) for each patient were obtained from averaging three pulse graphs. We departed from an average of 60 graphs (and more), the standard established in the literature, because of the cooling test specification, which causes huge thermodynamic parameter changeability in the plexus mass of the small finger under pulse waves coming one after another. A longer measurement time will reflect the thermal drift of the tested area in a direction to compensate for the reduced temperature. In the control group, all subjects showed an increase in planimetric indicators during the cooling test verified by computerized photoplethysmography. In the study group visual verification of the cooling test was positive in eight cases (6.2%) and the vibration perception threshold test was positive in seven cases (5.5%), but in computerized photoplethysmography the planimetric indicators decreased after cooling in 87 (67.4%) cases. Computer photoplethysmography is highly specific and shows greater sensitivity in detecting preclinical forms of vascular-type vibration syndrome when compared with palesthesiometry, the visually verified cooling test and the questionnaire. The proposed test enables the detection of vascular disorders in the prodromal period and gives time for preventive measures to be taken.
引用
收藏
页码:353 / 369
页数:17
相关论文
共 45 条
[21]  
Koradecka D, 1979, Pol Przegl Radiol Med Nukl, V43, P181
[22]  
KUKULIS I, 2000, INT ANGIOLOGY S1, V19, P33
[23]   Spectral analysis of AC and DC components of the pulse photoplethysmograph at rest and during induction of anaesthesia [J].
Larsen, PD ;
Harty, M ;
Thiruchelvam, M ;
Galletly, DC .
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1997, 14 (02) :89-95
[24]   ELEVATED ANTICARDIOLIPIN ANTIBODIES IN A PATIENT WITH VIBRATION-WHITE-FINGER, VALVULAR HEART-DISEASE AND PSORIATIC-ARTHRITIS [J].
MCHUGH, NJ ;
ELVINS, DM ;
RING, EFJ .
CLINICAL RHEUMATOLOGY, 1993, 12 (01) :70-73
[25]  
MITAS A., 1987, POM AUTOMAT KONTR, V7, P148
[26]  
NAGOTA C, 1993, INT ARCH OCC ENV HEA, V64, P587
[27]   The variability of the photoplethysmographic signal - a potential method for the evaluation of the autonomic nervous system [J].
Nitzan, M ;
Babchenko, A ;
Khanokh, B ;
Landau, D .
PHYSIOLOGICAL MEASUREMENT, 1998, 19 (01) :93-102
[28]  
Nitzan Meir, 1994, Journal of Basic and Clinical Physiology and Pharmacology, V5, P269
[29]  
NOWAK H, 1986, LEK WOJSK, V11, P701
[30]  
OZOLS M, 2001, P INT C BIOM ENG KTU, P24