Detection limit of polymeric membrane potentiometric ion sensors: how can we go down to trace levels?

被引:48
作者
Mi, YM [1 ]
Mathison, S [1 ]
Goines, R [1 ]
Logue, A [1 ]
Bakker, E [1 ]
机构
[1] Auburn Univ, Dept Chem, Auburn, AL 36849 USA
关键词
D O I
10.1016/S0003-2670(99)00396-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chemical reasons that may dictate the lower detection limit of polymeric membrane ion-selective electrode are discussed in terms of a possible leaching process of measuring ions from the membrane into the sample. As such electrode membranes are measured under zero current conditions, the charge of such released ions must be compensated for. Three distinct mechanisms are discussed: co-diffusion of measuring ions and counteranions from the backfilling solution into the sample, counter-diffusion of measuring ions and interfering ions of the same charge, and simple partitioning of measuring ions with the lipophilic ion-exchangers. A number of experiments are performed to illustrate these different mechanisms. Silver-selective electrode membranes are studied where the decrease in backfilling electrolyte concentration leads to detection limit variations from 10(-5.3) to 10(-8) M. The leaching behavior of sodium tetraphenylborate as anionic membrane additives is shown to be difficult to quantify in membranes containing no ionophore. Interestingly, much of the additive seems to leave the membrane in just a few minutes after water exposure. The presence of a neutral ionophore in the membrane is expected to slow this process. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:103 / 111
页数:9
相关论文
共 28 条
[1]  
Ammann, 1986, ION SELECTIVE MICROE
[2]   Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1061-1069
[3]   SELECTIVITY OF POLYMER MEMBRANE-BASED ION-SELECTIVE ELECTRODES - SELF-CONSISTENT MODEL DESCRIBING THE POTENTIOMETRIC RESPONSE IN MIXED ION SOLUTIONS OF DIFFERENT CHARGE [J].
BAKKER, E ;
MERUVA, RK ;
PRETSCH, E ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3021-3030
[4]   LIPOPHILICITY OF TETRAPHENYLBORATE DERIVATIVES AS ANIONIC SITES IN NEUTRAL CARRIER-BASED SOLVENT POLYMERIC MEMBRANES AND LIFETIME OF CORRESPONDING ION-SELECTIVE ELECTROCHEMICAL AND OPTICAL SENSORS [J].
BAKKER, E ;
PRETSCH, E .
ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) :7-17
[5]   Ion-selective electrodes based on two competitive ionophores for determining effective stability constants of ion-carrier complexes in solvent polymer membranes [J].
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :295-302
[6]   Determination of improved selectivity coefficients of polymer membrane ion-selective electrodes by conditioning with a discriminated ion [J].
Bakker, E .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (04) :L83-L85
[7]   DETECTION LIMIT OF ION-SELECTIVE BULK OPTODES AND CORRESPONDING ELECTRODES [J].
BAKKER, E ;
WILLER, M ;
PRETSCH, E .
ANALYTICA CHIMICA ACTA, 1993, 282 (02) :265-271
[8]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[9]   Origin of anion response of solvent polymeric membrane based silver ion-selective electrodes [J].
Bakker, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 35 (1-3) :20-25
[10]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687