DETECTION LIMIT OF ION-SELECTIVE BULK OPTODES AND CORRESPONDING ELECTRODES

被引:64
作者
BAKKER, E [1 ]
WILLER, M [1 ]
PRETSCH, E [1 ]
机构
[1] SWISS FED INST TECHNOL, DEPT ORGAN CHEM, UNIV STR 16, CH-8092 ZURICH, SWITZERLAND
关键词
ION-SELECTIVE ELECTRODES; LEAD-SENSITIVE OPTODE;
D O I
10.1016/0003-2670(93)80210-C
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The detection limit of a highly selective Pb2+-sensitive optode based on a solvent polymeric membrane phase is compared to the corresponding Pb2+-electrode. For this purpose, a practical definition of the detection limit for optodes is presented. Whereas the optode phase has an incorporated Pb2+-selective ionophore and H+-selective chromoionophore, the ion-selective electrode has no chromoionophore, but otherwise equal composition. It is shown that both optode and electrode are responding to the free ion activity of Pb2+ in the sample, which may be buffered by the use of suitable ligands such as NTA and EDTA. The detection limit of the optode (10(-13.1) M) has been found to be much lower than that of the electrode (10(-9.2) M), but with sample activities of less than 10(-11.5) M, response times of more than 60 h have been observed with EDTA as metal ion buffer. This is possibly due to a slow decomplexation step of the EDTA-Pb2+ complex.
引用
收藏
页码:265 / 271
页数:7
相关论文
共 28 条
  • [1] INTRACELLULAR NEUTRAL CARRIER-BASED CA-2+ MICROELECTRODE WITH SUBNANOMOLAR DETECTION LIMIT
    AMMANN, D
    BUHRER, T
    SCHEFER, U
    MULLER, M
    SIMON, W
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1987, 409 (03): : 223 - 228
  • [2] AMMANN D, 1983, ION SEL ELECTRODE R, V5, P3
  • [3] [Anonymous], 1976, PURE APPL CHEM, V48, P127
  • [4] FIBEROPTIC CHEMICAL SENSORS
    ARNOLD, MA
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (21) : A1015 - A1025
  • [5] SELECTIVITY OF ION-SENSITIVE BULK OPTODES
    BAKKER, E
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (17) : 1805 - 1812
  • [6] SYNTHESIS AND CHARACTERIZATION OF NEUTRAL HYDROGEN ION-SELECTIVE CHROMOIONOPHORES FOR USE IN BULK OPTODES
    BAKKER, E
    LERCHI, M
    ROSATZIN, T
    RUSTERHOLZ, B
    SIMON, W
    [J]. ANALYTICA CHIMICA ACTA, 1993, 278 (02) : 211 - 225
  • [7] ANION SELECTIVITIES OF TRIFLUOROACETOPHENONE DERIVATIVES AS NEUTRAL IONOPHORES IN SOLVENT-POLYMERIC MEMBRANES
    BEHRINGER, C
    LEHMANN, B
    HAUG, JP
    SEILER, K
    MORF, WE
    HARTMAN, K
    SIMON, W
    [J]. ANALYTICA CHIMICA ACTA, 1990, 233 (01) : 41 - 47
  • [8] KINETICS OF THE EXCHANGE OF NICKEL ETHYLENEDIAMINETETRAACETATE ION WITH NICKELOUS ION
    COOK, CM
    LONG, FA
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1958, 80 (01) : 33 - 37
  • [9] LIFETIME OF NEUTRAL-CARRIER-BASED LIQUID MEMBRANES IN AQUEOUS SAMPLES AND BLOOD AND THE LIPOPHILICITY OF MEMBRANE-COMPONENTS
    DINTEN, O
    SPICHIGER, UE
    CHANIOTAKIS, N
    GEHRIG, P
    RUSTERHOLZ, B
    MORF, WE
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (06) : 596 - 603
  • [10] REFERENCE ELECTRODE WITH FREE-FLOWING FREE-DIFFUSION LIQUID JUNCTION
    DOHNER, RE
    WEGMANN, D
    MORF, WE
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (12) : 2585 - 2589