Regional myocardial long-axis strain and strain rate measured by different tissue Doppler and speckle tracking echocardiography methods: a comparison with tagged magnetic resonance imaging

被引:77
作者
Amundsen, Brage H. [1 ]
Crosby, Jonas [1 ]
Steen, Per Arvid [2 ]
Torp, Hans [1 ]
Slordahl, Stig A. [1 ,3 ]
Stoylen, Asbjorn [1 ,3 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, MTFS, N-7489 Trondheim, Norway
[2] Univ Trondheim Hosp, St Olavs Hosp, Dept Med Imaging, Trondheim, Norway
[3] Univ Trondheim Hosp, St Olavs Hosp, Dept Cardiol, Trondheim, Norway
来源
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY | 2009年 / 10卷 / 02期
关键词
Echocardiography; Method comparison; MRI; Strain; Speckle tracking; Tissue Doppler; DOBUTAMINE STRESS ECHOCARDIOGRAPHY; 2-DIMENSIONAL SPECKLE; AUTOMATED-ANALYSIS; INCREMENTAL VALUE; VALIDATION; DEFORMATION; ULTRASOUND; TIME;
D O I
10.1093/ejechocard/jen201
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Compare four different echocardiographic methods, based on tissue Doppler imaging (TDI) and speckle tracking (ST) separately or combined, for long-axis strain and strain rate (SR) measurements, using magnetic resonance imaging (MRI) tagging as a reference. In 21 subjects (10 with myocardial infarction) peak systolic strain and systolic and early diastolic SR were measured by four different echo methods: (i) two-dimensional (2D) strain (B-mode); (ii) ST (custom software) of segment end-points (B-mode); (iii) similar to (ii), but combining ST with tissue Doppler tracking; (iv) strain from tissue Doppler velocity gradients (VG). Agreement with MRI tagging was better for strain than for SR. Ninety-five per cent limits of agreement were wider for the TDI-VG method, and 2D strain showed negative bias compared with MRI tagging and the other echo methods. Reproducibility was better for 2D strain than for MRI tagging and the other echo methods. ST alone or combined with TDI seems to be suitable for automated measurements of regional myocardial deformation. The study gives important information on the strengths and weaknesses of the different methods, which is important for further development to increase accuracy and applicability.
引用
收藏
页码:229 / 237
页数:9
相关论文
共 20 条
  • [1] Automatic timing of aortic valve closure in apical tissue Doppler images
    Aase, SA
    Stoylen, A
    Ingul, CB
    Frigstad, S
    Torp, H
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (01) : 19 - 27
  • [2] Noninvasive myocardial strain measurement by speckle tracking echocardiography - Validation against sonomicrometry and tagged magnetic resonance imaging
    Amundsen, BH
    Helle-Valle, T
    Edvardsen, T
    Torp, H
    Crosby, J
    Lyseggen, E
    Stoylen, A
    Ihlen, H
    Lima, JAC
    Smiseth, OA
    Slordahl, SA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 789 - 793
  • [3] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [4] Comparison of two-dimensional speckle and tissue velocity based strain and validation with harmonic phase magnetic resonance imaging
    Cho, Goo-Yeong
    Chan, Jonathan
    Leano, Rodel
    Strudwick, Mark
    Marwick, Thomas H.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (11) : 1661 - 1666
  • [5] Quantitative assessment of intrinsic regional myocardial deformation by Doppler strain rate echocardiography in humans - Validation against three-dimensional tagged magnetic resonance imaging
    Edvardsen, T
    Gerber, BL
    Garot, J
    Bluemke, DA
    Lima, JAC
    Smiseth, OA
    [J]. CIRCULATION, 2002, 106 (01) : 50 - 56
  • [6] Incremental value of strain rate analysis as an adjunct to wall-motion scoring for assessment of myocardial viability by dobutamine echocardiography - A follow-up study after revascularization
    Hanekom, L
    Jenkins, C
    Jeffries, L
    Case, C
    Mundy, J
    Hawley, C
    Marwick, TH
    [J]. CIRCULATION, 2005, 112 (25) : 3892 - 3900
  • [7] Comparison of two-dimensional speckle and tissue Doppler strain measurement during dobutamine stress echocardiography: an angiographic correlation
    Hanekom, Lizelle
    Cho, Goo-Yeong
    Leano, Rodel
    Jeffriess, Leanne
    Marwick, Thomas H.
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 (14) : 1765 - 1772
  • [8] Real-time strain rate imaging of the left ventricle by ultrasound
    Heimdal, A
    Stoylen, A
    Torp, H
    Skjaerpe, T
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (11) : 1013 - 1019
  • [9] Automated analysis of strain rate and strain: Feasibility and clinical implications
    Ingul, CB
    Torp, H
    Aase, SA
    Berg, S
    Stoylen, A
    Slordahl, SA
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (05) : 411 - 418
  • [10] Automated analysis of myocardial deformation at dobutamine stress echocardiography - An angiographic validation
    Ingul, Charlotte Bjork
    Stoylen, Asbjorn
    Slordahl, Stig A.
    Wiseth, Rune
    Burgess, Malcolm
    Marwick, Thomas H.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (15) : 1651 - 1659