Value of digital volume tomography in patients with conductive hearing loss

被引:38
作者
Dalchow, CV
Weber, AL
Bien, S
Yanagihara, N
Werner, JA
机构
[1] Univ Marburg, Dept Otorhinolaryngol Head & Neck Surg, D-35037 Marburg, Germany
[2] Massachusetts Eye & Ear Infirm, Dept Radiol, Boston, MA 02114 USA
[3] Univ Marburg, Dept Neuroradiol, D-35037 Marburg, Germany
[4] Takanoko Hosp, Dept Otolaryngol Head & Neck Surg, Takanoko, Japan
关键词
digital volume tomography; radiology; middle ear; temporal bone; middle-ear implant; ossicular chain; conductive hearing loss;
D O I
10.1007/s00405-005-0995-1
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Digital volume tomography (DVT) is an extension of panoramic tomography. With this diagnostic technique, characterized by high resolution, a narrow section width (0.125 mm) and three-dimensional display, small pathological processes can be well visualized. Twenty-five patients with the history of a progressive hearing loss were examined with DVT (Accu-I-tomo, Morita, Japan). The results were compared with pre- and intraoperative findings to evaluate the diagnostic value of DVT in cases of erosion of the ossicular chain. With high resolution and artifact-free demonstration of the middle ear and the ossicular chain, it was possible to define its continuity preoperatively by DVT in all 25 cases. An intact ossicular chain was found by DVT in 13 cases and was later confirmed by surgery. The predicted erosion of the ossicles was verified in 12 patients, and a tympanoplasty type III was performed. Digital volume tomography is an excellent technique to examine the middle ear cleft and inner ear, and expands the application of diagnostic possibilities in the lateral skull base. Therefore, improvement in preoperative diagnosis is achieved along with more accurate planning of the surgical procedure. Digital volume tomography delivers a small radiation dose with a high resolution and a low purchase price for the equipment.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 31 条
[1]   Development of a compact computed tomographic apparatus for dental use [J].
Arai, Y ;
Tammisalo, E ;
Iwai, K ;
Hashimoto, K ;
Shinoda, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :245-248
[2]  
Arai Y, 2000, JPN DENT RADIOL, V40, P145
[3]   CT and MR imaging of congenital abnormalities of the inner ear and internal auditory canal [J].
Casselman, JW ;
Offeciers, EF ;
De Foer, B ;
Govaerts, P ;
Kuhweide, R ;
Somers, T .
EUROPEAN JOURNAL OF RADIOLOGY, 2001, 40 (02) :94-104
[4]   3D volume rendering using multislice CT for dental implants [J].
Cavalcanti, MGP ;
Ruprecht, A ;
Vannier, MW .
DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (04) :218-223
[5]  
CHAKERES DW, 1984, AM J NEURORADIOL, V5, P297
[6]  
FISCH U, 1994, TYMPANOPLASTY MASTOI, P44
[7]  
Fuhrmann A, 2003, Int J Comput Dent, V6, P129
[8]   DIAGNOSIS OF THE OSSICULAR CHAIN IN THE MIDDLE-EAR BY HIGH-RESOLUTION CT [J].
FUSE, T ;
AOYAGI, M ;
KOIKE, Y ;
SUGAI, Y .
ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 1992, 54 (05) :251-254
[9]   CT and MRI of the petrous bone [J].
Grees, H ;
Baum, U ;
Römer, W ;
Tomandl, B ;
Bautz, W .
HNO, 2002, 50 (10) :906-+
[10]   3-DIMENSIONAL CT-IMAGING OF THE OSSICULAR CHAIN [J].
HERMANS, R ;
FEENSTRA, L ;
MARCHAL, G ;
BAERT, AL .
CLINICAL OTOLARYNGOLOGY, 1995, 20 (05) :475-478