A fast LC-APCI/MS method for analyzing benzodiazepines in whole blood using monolithic support

被引:34
作者
Bugey, A
Rudaz, S
Staub, C
机构
[1] Univ Geneva, Inst Forens Med, CH-1211 Geneva 4, Switzerland
[2] Univ Geneva, Lab Pharmaceut Analyt Chem, CH-1211 Geneva 4, Switzerland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2006年 / 832卷 / 02期
关键词
APCI; benzodiazepines; LC-MS; monolithic column; validation;
D O I
10.1016/j.jchromb.2006.01.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and fast procedure was developed for the simultaneous determination of eight benzodiazepines (BZDs) in whole blood using liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS). Sample pretreatment was carried out using a simple liquid-liquid extraction (LLE) with n-butylchloride, and chromatographic separation was performed using a monolithic silica column to speed up the analytical process. APCI and electrospray ionization (ESI) were compared. Whereas both ionization techniques appeared suitable for BZDs, APCI was found to be slightly more sensitive, especially for the determination of frequently low-dosed compounds. The method was validated according to the guidelines of the "Societe Francaise des Sciences et Techniques Pharmaceutiques" (SFSTP) in the concentration range of 2.5-500 mu g/L. The limit of quantification (LOQ) was 2.5 mu g/L for all the compounds. Validation data including linearity, precision, and trueness were obtained, allowing subtherapeutic quantification of frequently low-dosed BZDs. The high selectivity of the mass spectrometer, along with the properties of the monolithic support, allowed unequivocal analysis of the eight compounds in less than 5 min. To demonstrate the potential of the method, it was used for the analysis of benzodiazepines in postmortem blood samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 30 条
[11]   ELECTRON-CAPTURE GAS-CHROMATOGRAPHY DETERMINATION OF BENZODIAZEPINES AND METABOLITES [J].
FERGUSON, JL ;
COURI, D .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1977, 1 (04) :171-174
[12]   Simultaneous determination of flunitrazepam and its metabolites in plasma and urine by HPLC/DAD after solid phase extraction [J].
He, WD ;
Parissis, N .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 16 (04) :707-715
[13]   The SFSTP guide on the validation of chromatographic methods for drug bioanalysis: from the Washington Conference to the laboratory [J].
Hubert, P ;
Chiap, P ;
Crommen, J ;
Boulanger, B ;
Chapuzet, E ;
Mercier, N ;
Bervoas-Martin, S ;
Chevalier, P ;
Grandjean, D ;
Lagorce, P ;
Lallier, M ;
Laparra, MC ;
Laurentie, M ;
Nivet, JC .
ANALYTICA CHIMICA ACTA, 1999, 391 (02) :135-148
[14]   Harmonization of strategies for the validation of quantitative analytical procedures -: A SFSTP proposal -: part I [J].
Hubert, P ;
Nguyen-Huu, JJ ;
Boulanger, B ;
Chapuzet, E ;
Chiap, P ;
Cohen, N ;
Compagnon, PA ;
Dewé, W ;
Feinberg, M ;
Lallier, M ;
Laurentie, M ;
Mercier, N ;
Muzard, G ;
Nivet, C ;
Valat, L .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (03) :579-586
[15]   Screening, library-assisted identification and validated quantification of 23 benzodiazepines, flumazenil, zaleplone, zolpidem and zopiclone in plasma by liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization [J].
Kratzsch, C ;
Tenberken, O ;
Peters, FT ;
Weber, AA ;
Kraemer, T ;
Maurer, HH .
JOURNAL OF MASS SPECTROMETRY, 2004, 39 (08) :856-872
[16]  
LeBeau MA, 2000, J FORENSIC SCI, V45, P1133
[17]   Automated on-line solid-phase extraction gas chromatography with nitrogen-phosphorus detection: Determination of benzodiazepines in human plasma [J].
Louter, AJH ;
Bosma, E ;
Schipperen, JCA ;
Vreuls, JJ ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY B, 1997, 689 (01) :35-43
[18]   Sensitive and specific determination of midazolam and 1-hydroxymidazolam in human serum by liquid chromatography-electrospray mass spectrometry [J].
Marquet, P ;
Baudin, O ;
Gaulier, JM ;
Lacassie, E ;
Dupuy, JL ;
Francois, B ;
Lachâtre, G .
JOURNAL OF CHROMATOGRAPHY B, 1999, 734 (01) :137-144
[19]   Matrix effect in quantitative LC/MS/MS analyses of biological fluids: A method for determination of finasteride in human plasma at picogram per milliliter concentrations [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :882-889
[20]  
MOOR C, 2000, J CHROMATOGR B, P93