Factors associated with the impossibility to obtain reliable liver stiffness measurements by means of Acoustic Radiation Force Impulse (ARFI) elastography-Analysis of a cohort of 1031 subjects

被引:77
作者
Bota, Simona [1 ]
Sporea, Ioan [1 ]
Sirli, Roxana [1 ]
Popescu, Alina [1 ]
Danila, Mirela [1 ]
Jurchis, Ana [1 ]
Gradinaru-Tascau, Oana [1 ]
机构
[1] Victor Babes Univ Med & Pharm Timisoara, Dept Gastroenterol & Hepatol, Timisoara, Romania
关键词
ARFI elastography; Liver stiffness; Liver fibrosis; Reliable measurements; Failed measurements; Unreliable measurements; CHRONIC HEPATITIS-C; TRANSIENT ELASTOGRAPHY; EXTRAHEPATIC CHOLESTASIS; TISSUE QUANTIFICATION; CLINICAL FEASIBILITY; OBESE-PATIENTS; FIBROSIS; DIAGNOSIS; METAANALYSIS; PERFORMANCE;
D O I
10.1016/j.ejrad.2013.11.019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Introduction: Acoustic Radiation Force Impulse (ARFI) elastography is a non-invasive technique for liver fibrosis assessment. Aim: To assess the feasibility of ARFI elastography in a large cohort of subjects and to identify factors associated with impossibility to obtain reliable liver stiffness (LS) measurements by means of this technique. Methods: Our retrospective study included 1031 adult subjects with or without chronic liver disease. In each subject LS was assessed by means of ARFI elastography. Failure of ARFI measurements was defined if no valid measurement was obtained after at least 10 shots and unreliable in the following situations: fewer than 10 valid shots; or median value of 10 valid measurements with a success rate (SR) <60% and/or an interquartile range interval (IQR) >= 30%. Results: Failure of LS measurements by means of ARFI was observed in 4 subjects (0.3%), unreliable measurements in 66 subjects (6.4%), so reliable measurements were obtained in 961 subjects (93.3%). In univariant analysis, the following risk factors were associated with failed and unreliable measurements: age over 58 years (OR = 0.49; 95% CI 0.30-0.80, p = 0.005), male gender (OR = 0.58; 95% CI 0.34-0.94, p = 0.04), BMI > 27.7 kg/m(2) (OR = 0.23, 95% CI 0.13-0.41, p < 0.0001). In multivariate analysis all the factors mentioned above were independently associated with the risk of failed and unreliable measurements. Conclusions: Reliable LS measurements by means of ARFI elastography were obtained in 93.3% of cases. Older age, higher BMI and male gender were associated with the risk of failed and unreliable measurements, but their influence is limited as compared with Transient Elastography. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:268 / 272
页数:5
相关论文
共 30 条
[1]
Acoustic Radiation Force Impulse Imaging for Differentiation of Thyroid Nodules [J].
Bojunga, Joerg ;
Dauth, Nina ;
Berner, Christian ;
Meyer, Gesine ;
Holzer, Katharina ;
Voelkl, Lisa ;
Herrmann, Eva ;
Schroeter, Hartmut ;
Zeuzem, Stefan ;
Friedrich-Rust, Mireen .
PLOS ONE, 2012, 7 (08)
[2]
The influence of aminotransferase levels on liver stiffness assessed by Acoustic Radiation Force Impulse Elastography: A retrospective multicentre study [J].
Bota, Simona ;
Sporea, Ioan ;
Peck-Radosavljevic, Markus ;
Sirli, Roxana ;
Tanaka, Hironori ;
Iijima, Hiroko ;
Saito, Hidetsugu ;
Ebinuma, Hirotoshi ;
Lupsor, Monica ;
Badea, Radu ;
Fierbinteanu-Braticevici, Carmen ;
Petrisor, Ana ;
Friedrich-Rust, Mireen ;
Sarrazin, Christoph ;
Takahashi, Hirokazu ;
Ono, Naofumi ;
Piscaglia, Fabio ;
Marinelli, Sara ;
D'Onofrio, Mirko ;
Gallotti, Anna ;
Salzl, Petra ;
Popescu, Alina ;
Danila, Mirela .
DIGESTIVE AND LIVER DISEASE, 2013, 45 (09) :762-768
[3]
Meta-analysis: ARFI elastography versus transient elastography for the evaluation of liver fibrosis [J].
Bota, Simona ;
Herkner, Harald ;
Sporea, Ioan ;
Salzl, Petra ;
Sirli, Roxana ;
Neghina, Adriana M. ;
Peck-Radosavljevic, Markus .
LIVER INTERNATIONAL, 2013, 33 (08) :1138-1147
[4]
FACTORS WHICH INFLUENCE THE ACCURACY OF ACOUSTIC RADIATION FORCE IMPULSE (ARFI) ELASTOGRAPHY FOR THE DIAGNOSIS OF LIVER FIBROSIS IN PATIENTS WITH CHRONIC HEPATITIS C [J].
Bota, Simona ;
Sporea, Ioan ;
Sirli, Roxana ;
Popescu, Alina ;
Jurchis, Ana .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (03) :407-412
[5]
Bota S, 2011, MED ULTRASON, V13, P135
[6]
Bota S, 2010, MED ULTRASON, V12, P213
[7]
Acoustic radiation force impulse: a new ultrasonographic technology for the widespread noninvasive diagnosis of liver fibrosis [J].
Boursier, Jerome ;
Isselin, Gael ;
Fouchard-Hubert, Isabelle ;
Oberti, Frederic ;
Dib, Nina ;
Lebigot, Jerome ;
Bertrais, Sandrine ;
Gallois, Yves ;
Cales, Paul ;
Aube, Christophe .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2010, 22 (09) :1074-1084
[8]
Pitfalls of Liver Stiffness Measurement: A 5-Year Prospective Study of 13,369 Examinations [J].
Castera, Laurent ;
Foucher, Juliette ;
Bernard, Pierre-Henri ;
Carvalho, Francoise ;
Allaix, Daniele ;
Merrouche, Wassil ;
Couzigou, Patrice ;
de Ledinghen, Victor .
HEPATOLOGY, 2010, 51 (03) :828-835
[9]
Alanine aminotransferase-based algorithms of liver stiffness measurement by transient elastography (Fibroscan) for liver fibrosis in chronic hepatitis B [J].
Chan, H. L. -Y. ;
Wong, G. L. -H. ;
Choi, P. C. -L. ;
Chan, A. W. -H. ;
Chim, A. M. -L. ;
Yiu, K. K. -L. ;
Chan, F. K. -L. ;
Sung, J. J. -Y. ;
Wong, V. W. -S. .
JOURNAL OF VIRAL HEPATITIS, 2009, 16 (01) :36-44
[10]
Noninvasive assessment of liver fibrosis via spleen stiffness measurement using acoustic radiation force impulse sonoelastography in patients with chronic hepatitis B or C [J].
Chen, S. -H. ;
Li, Y. -F. ;
Lai, H. -C. ;
Kao, J. -T. ;
Peng, C. -Y. ;
Chuang, P. -H. ;
Su, W. -P. ;
Chiang, I. -P. .
JOURNAL OF VIRAL HEPATITIS, 2012, 19 (09) :654-663