The Smart-Scan-Technique in spiral computed tomography. A new method for dose reduction.

被引:39
作者
Giacomuzzi, SM
Erckert, B
Schopf, T
Freund, MC
Springer, P
Dessl, A
Jaschke, W
机构
[1] UNIV INNSBRUCK, INST RADIODIAGNOST, A-6020 INNSBRUCK, AUSTRIA
[2] UNIV INNSBRUCK, INST STRAHLENSCHUTZ & DOSIMETRIE, A-6020 INNSBRUCK, AUSTRIA
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1996年 / 165卷 / 01期
关键词
spiral CT; dose reduction; phantoms; image quality;
D O I
10.1055/s-2007-1015707
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In this article a new method - the Smart-Scan-Technique - for dose reduction during spiral computed tomography is described. This technique allones a dynamical adaptation of the tube current according to the measured local density structure form and absorption values of the object of interest. Its clinical applicability for dose reduction is investigated. In addition, changes in image quality are evaluated. Methods: Specially designed, water filled plexiglas-phantoms, an Alderson-Rando phantom, and 20 patients were used to simulate possible measures of patients within the thoracic and abdominal region. For those two regions the dose reduction, the modulation transfer function, and the pixel noise were measured. Results: Depending on patient geometry dose reduction up to 20% could be achieved with the Smart-Scan-Technique. This technique also enabled a decrease of the modulation transfer function and an increase of the pixel noise by 8%. Conclusion: Relevant dose reductions can be achieved by applying the Smart-Scan-Technique in spiral computed tomography.
引用
收藏
页码:10 / 16
页数:7
相关论文
共 11 条
[1]  
BERNHARDT J, 1995, MED PHYSIK, V1, P33
[2]   A PRACTICAL METHOD TO MEASURE THE MTF OF CT SCANNERS [J].
DROEGE, RT ;
MORIN, RL .
MEDICAL PHYSICS, 1982, 9 (05) :758-759
[3]  
*GE MED SYST, 1994, CT HISP ADV SYST, P15
[4]  
HOLSWORTH DW, 1993, MED PHYS, V20, P449
[5]   RADIATION EXPOSURE DURING CT USING STANDARD AND SPIRAL TECHNIQUES [J].
LANGKOWSKI, JH ;
POGODA, P ;
HESS, A .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (01) :3-11
[6]  
MAJO JR, 1995, AM J ROENTGENOL, V164, P603
[7]  
MURPHY F, 1985, BRIT J RADIOL, V58, P1197, DOI 10.1259/0007-1285-58-696-1197
[8]  
Panzer W, 1988, Rofo, V149, P534, DOI 10.1055/s-2008-1048398
[9]   RADIATION-DOSIMETRY SURVEY OF COMPUTED-TOMOGRAPHY SYSTEMS FROM 10 MANUFACTURERS [J].
SHOPE, TB ;
MORGAN, TJ ;
SHOWALTER, CK ;
PENTLOW, KS ;
ROTHENBERG, LN ;
WHITE, DR ;
SPELLER, RD .
BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (649) :60-69
[10]  
1993, SIEMENS AKTIENGESELL, V1, P14