Prospective evaluation of risk factors for bloodstream infection in patients receiving home infusion therapy

被引:108
作者
Tokars, JI
Cookson, ST
McArthur, MA
Boyer, CL
McGeer, AJ
Jarvis, WR
机构
[1] Ctr Dis Control & Prevent, Hosp Infect Program, Atlanta, GA 30333 USA
[2] Mt Sinai Hosp, Dept Microbiol, Toronto, ON M5G 1X5, Canada
[3] Princess Margaret Hosp, Toronto, ON M4X 1K9, Canada
[4] Cleveland Clin Fdn, Cleveland, OH 44195 USA
关键词
D O I
10.7326/0003-4819-131-5-199909070-00004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Intravenous therapy in the outpatient and home settings is commonplace for many diseases and nutritional disorders. Few data are available on the rate of and risk factors for bloodstream infection among patients receiving such therapy. Objective: To determine rates of and risk factors for bloodstream infection among patients receiving home infusion therapy. Design: Prospective, observational cohort study. Setting: Cleveland, Ohio, and Toronto, Ontario, Canada. Patients: Patients receiving home infusion therapy through a central or midline catheter. Measurements: Primary laboratory-confirmed bloodstream infection. Results: Among 827 patients (988 catheters), the most common diagnoses were infections other than HIV (67%), cancer (24%), nutritional and digestive disease (17%), heart disease (14%), receipt of bone marrow or solid organ transplants (11%), and HIV infection (7%). Sixty-nine bloodstream infections occurred during 69 532 catheter-days (0.99 infections per 1000 days). In a Cox regression model with time-dependent covariates, independent risk factors for bloodstream infection were recent receipt of a bone marrow transplant (hazard ratio, 5.8 [95% CI, 3.0 to 11.3]), receipt of total parenteral nutrition (hazard ratio, 4.1 [CI, 2.3 to 7.2]), receipt of therapy outside the home (for example, in an outpatient clinic or physician's office) (hazard ratio, 3.6 [CI, 2.2 to 5.9]), use of a multilumen catheter (hazard ratio, 2.8 [CI, 1.7 to 4.7]), and previous bloodstream infection (hazard ratio, 2.5 [CI, 1.5 to 4.2]). Rates of bloodstream infection per 1000 catheter-days varied from 0.16 for patients with none of these 5 risk factors to 6.77 for patients with 3 or more risk factors. Centrally inserted venous catheters were associated with a higher risk than implanted ports were, but the difference was not statistically significant. Conclusion: Bloodstream infections seem to be infrequent among outpatients receiving infusions through central and midline catheters. However, the rate of infection increases with bone marrow transplantation, parenteral nutrition, infusion therapy in a hospital clinic or physician's office, and use of multilumen catheters. Compared with implanted ports or peripherally inserted catheters, centrally inserted venous catheters may confer greater risk for bloodstream infection.
引用
收藏
页码:340 / +
页数:9
相关论文
共 25 条
[1]  
CAMPION E, 1998, NEW ENGL J MED, V333, P1213
[2]  
Cookson ST, 1998, INFECT CONT HOSP EP, V19, P23
[3]   BLOOD-STREAM INFECTIONS ASSOCIATED WITH A NEEDLELESS INTRAVENOUS-INFUSION SYSTEM IN PATIENTS RECEIVING HOME INFUSION THERAPY [J].
DANZIG, LE ;
SHORT, LJ ;
COLLINS, K ;
MAHONEY, W ;
SEPE, S ;
BLAND, L ;
JARVIS, WR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 273 (23) :1862-1864
[4]   Bloodstream infection associated with needleless device use and the importance of infection-control practices in the home health care setting [J].
Do, AN ;
Ray, BJ ;
Banerjee, SN ;
Illian, AE ;
Barnett, BJ ;
Pham, MH ;
Hendricks, KA ;
Jarvis, WR .
JOURNAL OF INFECTIOUS DISEASES, 1999, 179 (02) :442-448
[5]   AN OVERVIEW OF NOSOCOMIAL INFECTIONS, INCLUDING THE ROLE OF THE MICROBIOLOGY LABORATORY [J].
EMORI, TG ;
GAYNES, RP .
CLINICAL MICROBIOLOGY REVIEWS, 1993, 6 (04) :428-442
[6]   Nosocomial coagulase-negative staphylococcal infections in bone marrow transplantation recipients with central vein catheter - A 5-year prospective study [J].
Engelhard, D ;
Elishoov, H ;
Strauss, N ;
Naparstek, E ;
Nagler, A ;
Simhon, A ;
Raveh, D ;
Slavin, S ;
Or, R .
TRANSPLANTATION, 1996, 61 (03) :430-434
[7]   SINGLE-LUMEN VERSUS TRIPLE-LUMEN CENTRAL CATHETER-RELATED SEPSIS - A PROSPECTIVE RANDOMIZED STUDY IN A CRITICALLY ILL POPULATION [J].
FARKAS, JC ;
NGAI, L ;
BLERIOT, JP ;
CHEVRET, S ;
GOLDSTEIN, FW ;
CARLET, J .
AMERICAN JOURNAL OF MEDICINE, 1992, 93 (03) :277-282
[8]   INFECTIOUS MORBIDITY ASSOCIATED WITH LONG-TERM USE OF VENOUS ACCESS DEVICES IN PATIENTS WITH CANCER [J].
GROEGER, JS ;
LUCAS, AB ;
THALER, HT ;
FRIEDLANDERKLAR, H ;
BROWN, AE ;
KIEHN, TE ;
ARMSTRONG, D .
ANNALS OF INTERNAL MEDICINE, 1993, 119 (12) :1168-1174
[9]   TRANSPARENT POLYURETHANE FILM AS AN INTRAVENOUS CATHETER DRESSING - A METAANALYSIS OF THE INFECTION RISKS [J].
HOFFMANN, KK ;
WEBER, DJ ;
SAMSA, GP ;
RUTALA, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 267 (15) :2072-2076
[10]  
HOWELL PB, 1995, CANCER, V75, P1367, DOI 10.1002/1097-0142(19950315)75:6<1367::AID-CNCR2820750620>3.0.CO