Flicker mitigation strategy for a doubly fed induction generator by torque control

被引:17
作者
Zhang, Yunqian [1 ,2 ]
Hu, Weihao [1 ]
Chen, Zhe [1 ]
Cheng, Ming [2 ]
Hu, Yanting [3 ]
机构
[1] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
[2] Southeast Univ, Sch Elect Engn, Nanjing 210096, Jiangsu, Peoples R China
[3] Glyndwr Univ, Inst Art Design & Technol, Wrexham LL11 2AW, Wales
关键词
WIND TURBINES;
D O I
10.1049/iet-rpg.2013.0029
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Owing to the rotational sampling of turbulence, wind shear and tower shadow effects grid connected variable speed wind turbines could lead to the power fluctuations which may produce flicker during continuous operation. A model of an megawatt (MW)-level variable speed wind turbine with a doubly fed induction generator is presented to investigate the flicker mitigation. Taking advantage of the large inertia of the wind turbine rotor, a generator torque control (GTC) strategy is proposed, so that the power oscillation is stored as the kinetic energy of the wind turbine rotor, thus the flicker emission could be reduced. The GTC scheme is proposed and designed according to the generator rotational speed. The simulations are performed on the national renewable energy laboratory 1.5 MW upwind reference wind turbine model. Simulation results show that damping the generator active power by GTC is an effective means for flicker mitigation of variable speed wind turbines during continuous operation.
引用
收藏
页码:91 / 99
页数:9
相关论文
共 14 条
[1]  
[Anonymous], VOLTAGE QUALITY ELEC
[2]   A Review of the State of the Art of Power Electronics for Wind Turbines [J].
Chen, Zhe ;
Guerrero, Josep M. ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (08) :1859-1875
[3]   Flicker Mitigation by Active Power Control of Variable-Speed Wind Turbines With Full-Scale Back-to-Back Power Converters [J].
Hu, Weihao ;
Chen, Zhe ;
Wang, Yue ;
Wang, Zhaoan .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (03) :640-649
[4]  
*IEC, 1997, 61000415 IEC
[5]  
Jonkman B. J., NRELEL50038230
[6]   Flicker emission of wind turbines during continuous operation [J].
Larsson, Å .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2002, 17 (01) :114-118
[7]   Comparative study on transient stability analysis of wind turbine generator system using different drive train models [J].
Muyeen, S. M. ;
Ali, Md. Hasan ;
Takahashi, R. ;
Murata, T. ;
Tamura, J. ;
Tomaki, Y. ;
Sakahara, A. ;
Sasano, E. .
IET RENEWABLE POWER GENERATION, 2007, 1 (02) :131-141
[8]  
Nguyen T. D., 2011, P IEEE GLOBECOM, P1
[9]  
Riziotis V.A., 2012, EWEA ANN EVENT, P1
[10]   Use of load control to regulate voltage on distribution networks with embedded generation [J].
Scott, NC ;
Atkinson, DJ ;
Morrell, JE .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2002, 17 (02) :510-515