Combination of signals from array coils using image-based estimation of coil sensitivity profiles

被引:101
作者
Bydder, M [1 ]
Larkman, DJ [1 ]
Hajnal, JV [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Hammersmith Hosp, Sch Med,MRC, Ctr Clin Sci, London W12 0HS, England
关键词
magnetic resonance imaging; image reconstruction; array coils; signal-to-noise ratio; bias;
D O I
10.1002/mrm.10092
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
It is well established that the optimal unbiased way to combine image data from array coils is a pixel-by-pixel sum of coil signals, with each signal weighted by the individual coil sensitivity at the location of the pixel. A pragmatic alternative combines the images from the coils as the square root of the sum of squares (SOS), which can reduce the signal-to-noise ratio (SNR) and introduce bias. This work describes how to replace coil sensitivity by an image-derived quantity that enables close to optimal signal combination up to a global intensity scaling. Typical scaling is by an individual coil sensitivity or a linear or SOS combination of the sensitivities of some or all of the coils in the array. The method decreases signal bias, improves SNR when coils have unequal noise levels, and can reduce image artifacts. It can produce phase-corrected data, which eliminates bias completely. In addition, the method allows images from arrays that include highly localized coils, such as a prostate coil and external pelvic array, to be combined with near-optimal SNR and an intensity modulation that makes them easier to view. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:539 / 548
页数:10
相关论文
共 20 条
  • [1] Generalized SMASH imaging
    Bydder, M
    Larkman, DJ
    Hajnal, JV
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) : 160 - 170
  • [2] Signal-to-noise measurements in magnitude images from NMR phased arrays
    Constantinides, CD
    Atalar, E
    McVeigh, ER
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) : 852 - 857
  • [3] A solid reusable endorectal receiver coil for magnetic resonance imaging of the prostate: Design, use, and comparison with an inflatable endorectal coil
    deSouza, NM
    Gilderdale, DJ
    Puni, R
    Coutts, GA
    Young, IR
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (05): : 801 - 804
  • [4] THE RICIAN DISTRIBUTION OF NOISY MRI DATA
    GUDBJARTSSON, H
    PATZ, S
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) : 910 - 914
  • [5] NOISE CORRELATIONS IN DATA SIMULTANEOUSLY ACQUIRED FROM MULTIPLE SURFACE COIL ARRAYS
    HAYES, CE
    ROEMER, PB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) : 181 - 191
  • [6] FAST MRI DATA ACQUISITION USING MULTIPLE DETECTORS
    HUTCHINSON, M
    RAFF, U
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (01) : 87 - 91
  • [7] Jakob PM, 1998, MAGN RESON MATER PHY, V7, P42
  • [8] Kyriakos WE, 2000, MAGNET RESON MED, V44, P301, DOI 10.1002/1522-2594(200008)44:2<301::AID-MRM18>3.0.CO
  • [9] 2-D
  • [10] An investigation into the use of sensitivity-encoded techniques to increase temporal resolution in dynamic contrast-enhanced breast imaging
    Larkman, DJ
    deSouza, NM
    Bydder, M
    Hajnal, JV
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) : 329 - 335