Fiducial-based targeting accuracy for external-beam radiotherapy

被引:100
作者
Murphy, MJ [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
fiducial alignment; radiosurgery; conformal radiotherapy; IMRT; patient positioning;
D O I
10.1118/1.1448823
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The accuracy of fiducial-based alignment of external radiotherapy beams is analyzed. The study considers three basic computational methods to determine the target position-the exact closed-form solution for three fiducials, the solution via singular value decomposition for four or more fiducials, and the iterative solution for any number of fiducials-and assesses their accuracy, robustness, and efficiency. Particular attention is paid to inaccuracies arising from the variability of fiducial positions in soft tissue. In nearly every test case it is found that all three solution methods, when properly implemented, yield the same result for the target position, but that the method of singular value decomposition must be modified to distinguish rotations from reflections. When an accurate measure of the rotation of the target site is needed, four fiducials give much better results than three, while more than five fiducials gain little further improvement. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:334 / 344
页数:11
相关论文
共 15 条
[1]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[2]   Stochastic problems in physics and astronomy [J].
Chandrasekhar, S .
REVIEWS OF MODERN PHYSICS, 1943, 15 (01) :0001-0089
[3]   PROSTATE MOTION DURING STANDARD RADIOTHERAPY AS ASSESSED BY FIDUCIAL MARKERS [J].
CROOK, JM ;
RAYMOND, Y ;
SALHANI, D ;
YANG, H ;
ESCHE, B .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :35-42
[4]   Estimating 3-D rigid body transformations: A comparison of four major algorithms [J].
Eggert, DW ;
Lorusso, A ;
Fischer, RB .
MACHINE VISION AND APPLICATIONS, 1997, 9 (5-6) :272-290
[5]  
GALL KP, 1993, MED PHYS, V20, P1153, DOI 10.1118/1.596969
[6]   ANALYSIS OF 3-D ROTATION FITTING [J].
KANATANI, K .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1994, 16 (05) :543-549
[7]   Respiratory-induced prostate motion: Quantification and characterization [J].
Malone, S ;
Crook, JM ;
Kendal, WS ;
Szanto, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (01) :105-109
[8]  
Murphy M J, 2000, Comput Aided Surg, V5, P278, DOI 10.3109/10929080009148895
[9]   An automatic six-degree-of-freedom image registration algorithm for image-guided frameless stereotaxic radiosurgery [J].
Murphy, MJ .
MEDICAL PHYSICS, 1997, 24 (06) :857-866
[10]  
MURPHY MJ, 2001, 5 INT STER RAD SOC C