MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS

被引:274
作者
BALTER, JM
SANDLER, HM
LAM, K
BREE, RL
LICHTER, AS
TENHAKEN, RK
机构
[1] Department of Radiation Oncology, University of Michigan, Ann Arbor, MI
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 31卷 / 01期
关键词
PROSTATE MOVEMENT; IMAGE REGISTRATION; CONFORMAL THERAPY;
D O I
10.1016/0360-3016(94)00382-U
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To measure the range and frequency of occurrence of intertreatment movement of the prostate gland over the course of radiotherapy, and to demonstrate that the prostate may move independently of the surrounding bones of the pelvis. Methods and Materials: Ten patients underwent implantation of radiopaque markers around the prostate. Orthogonal portal films were taken at multiple stages during the course of treatment and digitized. An image registration tool was used to solve for film detector placement and, subsequently, to determine positional changes between structures on a reference portal image pair and all subsequent pairs for each patient. Transformations describing prostate movement were measured independently of those describing setup variations of the pelvic girdle. Results: Translation and/or rotation of the prostate was detected in 70% of the treatments for which films were taken. The maximum measured displacement was 7.5 mm along a major axis. Typical translations of the prostate were between 0-4 mm. The translation and rotation had a predominant direction, suggesting a natural axis for prostate movement. Conclusion: Although significant prostate displacement can occur between treatments, the typical range of movement seen along a major axis was less than 5 mm. Proper treatment planning should consider the movement of the target independent of surrounding bony anatomy. Advances in online portal imaging, image registration, and dynamic field shaping may permit shaped fields that encompass the prostate gland in its position at the time of treatment, allowing for the use of smaller fields while ensuring proper target coverage.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 12 条
  • [1] ONLINE REPOSITIONING DURING TREATMENT OF THE PROSTATE - A STUDY OF POTENTIAL LIMITS AND GAINS
    BALTER, JM
    CHEN, GTY
    PELIZZARI, CA
    KRISHNASAMY, S
    RUBIN, S
    VIJAYAKUMAR, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (01): : 137 - 143
  • [2] CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS
    BALTER, JM
    PELIZZARI, CA
    CHEN, GTY
    [J]. MEDICAL PHYSICS, 1992, 19 (02) : 329 - 334
  • [3] ANALYSIS OF PROSTATE AND SEMINAL-VESICLE MOTION
    BEARD, CJ
    BUSSIERE, MR
    PLUNKETT, ME
    COLEMAN, CN
    KIJEWSKI, PK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 : 136 - 136
  • [4] A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS)
    BOYER, AL
    ANTONUK, L
    FENSTER, A
    VANHERK, M
    MEERTENS, H
    MUNRO, P
    REINSTEIN, LE
    WONG, J
    [J]. MEDICAL PHYSICS, 1992, 19 (01) : 1 - 16
  • [5] EVALUATION OF CHANGES IN THE LOCATION AND SHAPE OF THE PROSTATE AND RECTUM DURING A 7 WEEK COURSE OF CONFORMAL RADIOTHERAPY
    FORMAN, JD
    MESINA, CF
    HE, T
    DEVI, SB
    BENJOSEF, E
    PELIZZARI, C
    VIJAYAKUMAR
    CHEN, GT
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 : 222 - 222
  • [6] HUNT M, 1989, MED PHYS, V16, P46
  • [7] VARIATION IN PROSTATE POSITION - QUANTITATION AND IMPLICATIONS FOR 3-DIMENSIONAL CONFORMAL RADIATION-THERAPY
    MELIAN, E
    KUTCHER, G
    LEIBEL, S
    ZELEFSKY, M
    BALDWIN, B
    FUKS, Z
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 : 137 - 137
  • [8] DEFINING IDEAL MARGINS FOR 6 FIELD CONFORMAL IRRADIATION OF LOCALIZED PROSTATE-CANCER
    PICKETT, B
    ROACH, M
    ROSENTHAL, S
    HORINE, P
    PHILLIPS, T
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 : 223 - 224
  • [9] LOCALIZATION OF THE PROSTATIC APEX FOR RADIATION-THERAPY USING IMPLANTED MARKERS
    SANDLER, HM
    BREE, RL
    MCLAUGHLIN, PW
    GROSSMAN, HB
    LICHTER, AS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (04): : 915 - 919
  • [10] SHALEV S, 1989, International Journal of Radiation Oncology, Biology, Physics, V17, P158