We used a new method, polarization sensing, to monitor the concentration of the fluorophore rhodamine 800 in an intralipid suspension and in chicken tissue. Rhodamine 800 (Rh800) could be excited at 648 nm using a laser pointer. We developed a simple device for measuring the combined emission from a highly polarized reference film and the unpolarized or orthogonally polarized emission of Rh800 from the scattering intralipid or tissue. The concentration of Rh800 in this medium was revealed by large changes in the polarization (P) with values of P ranging from 0.8 to -0.9. It is possible to vary the sensitive Rh800 concentration range by variation of the detected emission wavelengths, orientation of the excitation polarizer, or fluorophore concentration in the reference film. Polarization sensing of fluorophores in tissue requires only steady-state detection, and can be accomplished with simple and/or portable electronics. Such devices may find use in electronic detection of ingested medicines based on transdermal detection of nontoxic long-wavelength fluorophores. (C) 1999 Academic Press.
引用
收藏
页码:204 / 211
页数:8
相关论文
共 29 条
  • [1] [Anonymous], SPECTROSCOPY POLARIZ
  • [2] INTRAVITAL DETECTION OF SKIN CAPILLARY ANEURYSMS BY VIDEOMICROSCOPY WITH INDOCYANINE GREEN IN PATIENTS WITH PROGRESSIVE SYSTEMIC-SCLEROSIS AND RELATED DISORDERS
    BOLLINGER, A
    SAESSELI, B
    HOFFMANN, U
    FRANZECK, UK
    [J]. CIRCULATION, 1991, 83 (02) : 546 - 551
  • [3] MICROELECTRONIC SYSTEMS FOR MONITORING AND ENHANCING PATIENT COMPLIANCE WITH MEDICATION REGIMENS
    CRAMER, JA
    [J]. DRUGS, 1995, 49 (03) : 321 - 327
  • [4] Devoisselle JM, 1997, P SOC PHOTO-OPT INS, V2980, P453, DOI 10.1117/12.273563
  • [5] Devoisselle JM, 1997, P SOC PHOTO-OPT INS, V2980, P293, DOI 10.1117/12.273514
  • [6] NONINVASIVE FLUORESCENCE DETECTION OF HEPATIC AND RENAL FUNCTION
    Dorshow, Richard B.
    Bugaj, Joseph E.
    Burleigh, B. Daniel
    Duncan, James R.
    Johnson, Michael A.
    Jones, William B.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 1998, 3 (03) : 340 - 345
  • [7] GRYCZYNSKI I, 1999, UNPUB
  • [8] HENSCHEN S, 1993, J MED, V24, P10
  • [9] DEVELOPMENT OF A NONINVASIVE MONITORING INSTRUMENT FOR SERUM INDOCYANINE GREEN-DYE CONCENTRATION
    KANDA, M
    NIWA, S
    [J]. APPLIED OPTICS, 1992, 31 (31): : 6668 - 6675
  • [10] ON THE DETERMINATION OF TRANSITION-MOMENT DIRECTIONS FROM ABSORPTION ANISOTROPY MEASUREMENTS
    KAWSKI, A
    GRYCZYNSKI, Z
    [J]. ZEITSCHRIFT FUR NATURFORSCHUNG SECTION A-A JOURNAL OF PHYSICAL SCIENCES, 1987, 42 (06): : 617 - 621