Model-Based Iterative Reconstruction Technique for Ultralow-Dose Chest CT Comparison of Pulmonary Nodule Detectability With the Adaptive Statistical Iterative Reconstruction Technique

被引:147
作者
Katsura, Masaki [1 ]
Matsuda, Izuru [1 ]
Akahane, Masaaki [1 ]
Yasaka, Koichiro [1 ]
Hanaoka, Shohei [1 ]
Akai, Hiroyuki [1 ]
Sato, Jiro [1 ]
Kunimatsu, Akira [1 ]
Ohtomo, Kuni [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Radiol, Tokyo 1138655, Japan
关键词
model-based iterative reconstruction; adaptive statistical iterative reconstruction; radiation dose; pulmonary nodule detection; SPIRAL COMPUTED-TOMOGRAPHY; EARLY LUNG-CANCER; IMAGE QUALITY; RADIATION; REDUCTION; HYBRID; OBSERVER; IMPACT; TOMOSYNTHESIS; IMPROVEMENT;
D O I
10.1097/RLI.0b013e31827efc3a
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: The purpose of this study was to evaluate whether model-based iterative reconstruction (MBIR) enables dose reduction over adaptive iterative reconstruction (ASIR) while maintaining diagnostic performance. Methods: In this institutional review board-approved and Health Insurance Portability and Accountability Act-compliant study, 59 patients (mean [SD] age, 64.7 [13.4] years) gave informed consent to undergo reference-, low-, and ultralow-dose chest computed tomography (CT) with 64-row multidetector CT. The reference-and low-dose CT involved the use of automatic tube current modulation with fixed noise indices (31.5 and 70.44 at 0.625 mm, respectively) and were reconstructed with 50% ASIR-filtered back projection blending. The ultralow-dose CT was acquired with a fixed tube current-time product of 5 mA s and reconstructed with MBIR. Two radiologists evaluated 2.5- and 0.625-mm-slice-thick axial images from low-dose ASIR and ultralow-dose MBIR, recorded the pattern of each nodule candidate, and assigned each a confidence score. A reference standard was established by a consensus panel of 2 different radiologists, who identified 84 noncalcified nodules with diameters of 4 mm or greater on reference-dose ASIR (ground-glass opacity, n = 18; partly solid, n = 11; solid, n = 55). Sensitivity in nodule detection was assessed using the McNemar test. Jackknife alternative free-response receiver operating characteristic (JAFROC) analysis was applied to assess the results including confidence scores. Results: Compared with the low-dose CT, a 78.1% decrease in dose-length product was seen with the ultralow-dose CT. No significant differences were observed between the low-dose ASIR and the ultralow-dose MBIR for overall nodule detection in sensitivity (P = 0.48-0.69) or the JAFROC analysis (P = 0.57). Likewise, no significant differences were seen for ground-glass opacity, partly solid, or solid nodule detection in sensitivity (P = 0.08-0.65) or the JAFROC analysis (P = 0.21-0.90). Conclusions: Model-based iterative reconstruction enables nearly an 80% reduction in radiation dose for chest CT from a low-dose level to an ultralow-dose level, without affecting nodule detectability.
引用
收藏
页码:206 / 212
页数:7
相关论文
共 45 条
[1]
AAPM, 2008, MEASUREMENT REPORTIN
[2]
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening [J].
Aberle, Denise R. ;
Adams, Amanda M. ;
Berg, Christine D. ;
Black, William C. ;
Clapp, Jonathan D. ;
Fagerstrom, Richard M. ;
Gareen, Ilana F. ;
Gatsonis, Constantine ;
Marcus, Pamela M. ;
Sicks, JoRean D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (05) :395-409
[3]
[Anonymous], CANC FACTS FIG 2012
[4]
Computed Tomography of the Lung in the High-Pitch Mode Is Breath Holding Still Required? [J].
Baumueller, Stephan ;
Alkadhi, Hatem ;
Stolzmann, Paul ;
Frauenfelder, Thomas ;
Goetti, Robert ;
Schertler, Thomas ;
Plass, Andre ;
Falk, Volkmar ;
Feuchtner, Gudrun ;
Scheffel, Hans ;
Desbiolles, Lotus ;
Leschka, Sebastian .
INVESTIGATIVE RADIOLOGY, 2011, 46 (04) :240-245
[5]
Impact of tumor size on outcomes after anatomic lung resection for stage 1A non-small cell lung cancer based on the current staging system [J].
Carr, Shamus R. ;
Schuchert, Matthew J. ;
Pennathur, Arjun ;
Wilson, David O. ;
Siegfried, Jill M. ;
Luketich, James D. ;
Landreneau, Rodney J. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 143 (02) :390-397
[6]
Survival of Patients With True Pathologic Stage I Non-Small Cell Lung Cancer [J].
Cerfolio, Robert J. ;
Bryant, Ayesha S. .
ANNALS OF THORACIC SURGERY, 2009, 88 (03) :917-923
[7]
Analysis of location specific observer performance data: Validated extensions of the jackknife free-response (JAFROC) method [J].
Chakraborty, Dev P. .
ACADEMIC RADIOLOGY, 2006, 13 (10) :1187-1193
[8]
Observer studies involving detection and localization: Modeling, analysis, and validation [J].
Chakraborty, DP ;
Berbaum, KS .
MEDICAL PHYSICS, 2004, 31 (08) :2313-2330
[9]
MAXIMUM-LIKELIHOOD ANALYSIS OF FREE-RESPONSE RECEIVER OPERATING CHARACTERISTIC (FROC) DATA [J].
CHAKRABORTY, DP .
MEDICAL PHYSICS, 1989, 16 (04) :561-568
[10]
Diagnostic Accuracy of Computed Tomography Using Lower Doses of Radiation for Patients With Crohn's Disease [J].
Craig, Orla ;
O'Neill, Siobhan ;
O'Neill, Fiona ;
McLaughlin, Patrick ;
McGarrigle, Annemarie ;
McWilliams, Sebastian ;
O'Connor, Owen ;
Desmond, Alan ;
Walsh, Elizabeth Kenny ;
Ryan, Max ;
Maher, Michael ;
Shanahan, Fergus .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2012, 10 (08) :886-892