Computed Tomography of the Lung in the High-Pitch Mode Is Breath Holding Still Required?

被引:61
作者
Baumueller, Stephan [2 ]
Alkadhi, Hatem [2 ,3 ,4 ]
Stolzmann, Paul [2 ,3 ,4 ]
Frauenfelder, Thomas [2 ]
Goetti, Robert [2 ]
Schertler, Thomas [2 ]
Plass, Andre [5 ]
Falk, Volkmar [5 ]
Feuchtner, Gudrun [2 ]
Scheffel, Hans [2 ,3 ,4 ]
Desbiolles, Lotus [2 ]
Leschka, Sebastian [1 ]
机构
[1] Cantonal Hosp St Gallen, Inst Radiol, CH-9007 St Gallen, Switzerland
[2] Univ Zurich Hosp, Inst Diagnost & Intervent Radiol, CH-8091 Zurich, Switzerland
[3] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[4] Harvard Univ, Sch Med, Boston, MA USA
[5] Univ Zurich Hosp, Cardiovasc Surg Clin, CH-8091 Zurich, Switzerland
关键词
computed tomography scanner; lung; breathing; HIGH-RESOLUTION CT; THIN-SECTION CT; ADAPTED EXAMINATION PROTOCOLS; SPIRAL VOLUMETRIC CT; RADIATION-EXPOSURE; PULMONARY NODULES; AORTIC-ANEURYSM; REDUCTION; ARTIFACTS; ENDOLEAKS;
D O I
10.1097/RLI.0b013e3181feee1a
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Objectives: To prospectively investigate whether the high-pitch mode (HPM) for computed tomography (CT) enables the diagnostic visualization of the lung parenchyma without suspended respiration. Materials and Methods: A total of 40 consecutive patients (age, 67 +/- 11 years) underwent 128-slice dual-source CT of the chest including nonenhanced, arterial, and venous phase of contrast. CT was performed in the HPM with a pitch of 3.2 during continuous breathing (group A) and during breath-hold (group B), and at standard pitch of 1 during deep-inspiratory breath-hold (group C). The 3 protocols were scanned in a random order in each patient. Two blinded readers independently assessed the image quality of 5 regions in both the lungs using a semiquantitative 3-point score. Image noise was measured as the standard deviation of attenuation. Presence and size of pulmonary nodules were noted and measured on each CT dataset. Lung volume was measured using dedicated semi-automated segmentation software. Results: Interobserver agreement for image quality ratings was excellent (kappa = 0.91). There were no significant differences in the number of lung regions having an image quality other than excellent between group A (2.5%) and B (1.5%, P = 0.48), whereas significantly less regions had impaired image quality in group B compared with group C (5.5%, P < 0.01). Image quality impairment in group C was because of breathing in 36% and cardiac pulsation in 64%. Image noise in group C (9 +/- 2 HU) was significantly lower than that in group B (30 +/- 2 HU, P < 0.001) whereas no significant difference was found between group A and B (P = 0.52). There were no significant differences for the depiction (P = 1.0) and size (P = 0.94) of lung nodules among the 3 modes. Average lung volume in group A was 75% +/- 15% of that in deep inspiration (group B/C) being significantly smaller (P < 0.05). Estimated effective radiation doses in group C and group B were 5.8 +/- 0.5 mSv and 1.6 +/- 0.1 mSv, respectively. Conclusions: CT of the lung can be accomplished using the HPM at a low radiation dose with a diagnostic image quality even without suspended respiration.
引用
收藏
页码:240 / 245
页数:6
相关论文
共 37 条
[1]
Respiratory instructions for CT examinations of the lungs: A hands-oil guide [J].
Bankier, Alexander A. ;
O'Donnell, Carl R. ;
Boiselle, Phillip M. .
RADIOGRAPHICS, 2008, 28 (04) :919-931
[2]
Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering [J].
Biederer, J ;
Reuter, M ;
Both, M ;
Muhle, C ;
Grimm, J ;
Graessner, J ;
Heller, M .
EUROPEAN RADIOLOGY, 2002, 12 (02) :378-384
[3]
Thin-section CT of the lung: Does electrocardiographic triggering influence diagnosis? [J].
Boehm, T ;
Willmann, JK ;
Hilfiker, PR ;
Weishaupt, D ;
Seifert, B ;
Crook, DW ;
Marincek, B ;
Wildermuth, S .
RADIOLOGY, 2003, 229 (02) :483-491
[4]
THORACIC HELICAL CT [J].
COSTELLO, P .
RADIOGRAPHICS, 1994, 14 (04) :913-918
[5]
SPIRAL CT OF THE THORAX [J].
COSTELLO, P .
SEMINARS IN ULTRASOUND CT AND MRI, 1994, 15 (02) :90-106
[6]
Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations [J].
Das, M ;
Mahnken, AH ;
Mühlenbruch, G ;
Stargardt, A ;
Weiss, C ;
Sennst, DA ;
Flohr, TG ;
Günther, RW ;
Wildberger, JE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (05) :1437-1443
[7]
VOLUMETRIC HIGH-RESOLUTION CT IN THE DIAGNOSIS OF INTERSTITIAL LUNG-DISEASE AND BRONCHIECTASIS - DIAGNOSTIC-ACCURACY AND RADIATION-DOSE [J].
ENGELER, CE ;
TASHJIAN, JH ;
ENGELER, CM ;
GEISE, RA ;
HOLM, JC ;
RITENOUR, ER .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) :31-35
[8]
Cardiac spiral dual-source CT with high pitch: a feasibility study [J].
Ertel, Dirk ;
Lell, Michael M. ;
Harig, Frank ;
Flohr, Thomas ;
Schmidt, Bernhard ;
Kalender, Willi A. .
EUROPEAN RADIOLOGY, 2009, 19 (10) :2357-2362
[9]
Quantitative Computed Tomography Liver Perfusion Imaging Using Dynamic Spiral Scanning With Variable Pitch Feasibility and Initial Results in Patients With Cancer Metastases [J].
Goetti, Robert ;
Leschka, Sebastian ;
Desbiolles, Lotus ;
Klotz, Ernst ;
Samaras, Panagiotis ;
von Boehmer, Lotta ;
Stenner, Frank ;
Reiner, Caecilia ;
Stolzmann, Paul ;
Scheffel, Hans ;
Knuth, Alexander ;
Marincek, Borut ;
Alkadhi, Hatem .
INVESTIGATIVE RADIOLOGY, 2010, 45 (07) :419-426
[10]
Low Dose High-Pitch Spiral Acquisition 128-Slice Dual-Source Computed Tomography for the Evaluation of Coronary Artery Bypass Graft Patency [J].
Goetti, Robert ;
Leschka, Sebastian ;
Baumueller, Stephan ;
Plass, Andre ;
Wieser, Monika ;
Desbiolles, Lotus ;
Stolzmann, Paul ;
Falk, Volkmar ;
Marincek, Borut ;
Alkadhi, Hatem ;
Feuchtner, Gudrun .
INVESTIGATIVE RADIOLOGY, 2010, 45 (06) :324-330