Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations

被引:40
作者
Das, M
Mahnken, AH
Mühlenbruch, G
Stargardt, A
Weiss, C
Sennst, DA
Flohr, TG
Günther, RW
Wildberger, JE
机构
[1] Univ Technol, RWTH, Univ Hosp, Dept Diagnost Radiol, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Inst Med Stat, D-5100 Aachen, Germany
[3] Inst Med Phys, Erlangen, Germany
[4] Siemens Med Solut, Computed Tomog, Forchheim, Germany
关键词
D O I
10.2214/ajr.184.5.01841437
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to develop a simple protocol for reduction of radiation exposure without loss of diagnostic information in chest 16-MDCT. MATERIALS AND METHODS. Two hundred and four patients underwent MDCT of the thorax (Somatom Sensation 16, Siemens). Group 1 was scanned using a standard protocol with 100 mAs(effective) (mAs(eff)). Group 2 was scanned using a dose modulation template (Care-Dose). Group 3 was scanned with mAs(eff) = body weight (kg). Group 4 was scanned with a combination of weight-adapted mAs(eff) and dose modulation. All other parameters were kept constant. Signal-to-noise ratio was assessed as an objective measurement for image quality, and subjective image quality was rated by three experienced radiologists on a 4-point scale. Effective dose was calculated using dedicated software. RESULTS. The mean noise measurement values were 8.31 H for the 100 mAs,(eff) protocol for the regression between weight and signal-to-noise (P < 0.0001), 9.08 H for group 2 (p < 0.0001), 9.0 H for group 3 (p = 0.5051), and 9.98 H for group 4 (p = 0.0152). The median image quality was 1 (1 = highest quality) in all subgroups. The mean effective dose was 6.83 mSv, 5.92 mSv, 4.73 mSv, and 3.97 mSv, respectively. The least correlation between weight and image noise was achieved for the individually weight-adapted protocol and in the weight-adapted with CareDose combination. CONCLUSION. By tube current time product adaptation (kg = mAs(eff)) combined with an online tube current modulation template, a well-balanced examination without significant loss of information was achieved for this specific scanner. Thus, individually adapted protocols for chest 16-MDCT can be recommended.
引用
收藏
页码:1437 / 1443
页数:7
相关论文
共 22 条
[1]  
*COMM EUR COMM, 1998, 16262 EUR
[2]   Spiral CT of the abdomen: Weight-adjusted dose reduction. [J].
Coppenrath, E ;
Schmid, C ;
Brandl, R ;
Szeimies, U ;
Hahn, K .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (01) :52-56
[3]   Advances in cardiac imaging with 16-section CT systems [J].
Flohr, TG ;
Schoepf, UJ ;
Kuettner, A ;
Halliburton, S ;
Bruder, H ;
Suess, C ;
Schmidt, B ;
Hofmann, L ;
Yucel, EK ;
Schaller, S ;
Ohnesorge, BM .
ACADEMIC RADIOLOGY, 2003, 10 (04) :386-401
[4]   Technical advances in multi-slice spiral CT [J].
Fuchs, T ;
Kachelriess, M ;
Kalender, WA .
EUROPEAN JOURNAL OF RADIOLOGY, 2000, 36 (02) :69-73
[5]   Dose reduction in CT by anatomically adapted tube current modulation. 1. Simulation studies [J].
Gies, M ;
Kalender, WA ;
Wolf, H ;
Suess, C ;
Madsen, MT .
MEDICAL PHYSICS, 1999, 26 (11) :2235-2247
[6]   Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose) [J].
Greess, H ;
Nömayr, A ;
Wolf, H ;
Baum, U ;
Lell, M ;
Böwing, B ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2002, 12 (06) :1571-1576
[7]   Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions [J].
Greess, H ;
Wolf, H ;
Baum, U ;
Lell, M ;
Pirkl, M ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2000, 10 (02) :391-394
[8]  
Greess H, 1999, ROFO-FORTSCHR RONTG, V170, P246
[9]   CT screening for lung cancer [J].
Henschke, CI ;
Yankelevitz, DF ;
Kostis, WJ .
SEMINARS IN ULTRASOUND CT AND MRI, 2003, 24 (01) :23-32
[10]   Survey of conventional and spiral CT doses [J].
Hidajat, N ;
Wolf, M ;
Nunnemann, A ;
Liersch, P ;
Gebauer, B ;
Teichgräber, U ;
Schröder, RJ ;
Felix, R .