Spiral CT of the abdomen: Weight-adjusted dose reduction.

被引:21
作者
Coppenrath, E [1 ]
Schmid, C [1 ]
Brandl, R [1 ]
Szeimies, U [1 ]
Hahn, K [1 ]
机构
[1] Univ Munich, Klinikum Innenstadt, Inst Radiol Diagnost, D-80336 Munich, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2001年 / 173卷 / 01期
关键词
spiral CT; noise; image quality; weight-adjusted dose reduction;
D O I
10.1055/s-2001-10226
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim of the study: The influence of weight-adjusted current application in spiral CT of the abdomen on noise was investigated in a clinical study. Patients and methods: In 77 routine abdominal CT investigations (120 kV, 8 mm, pitch 1.5) the patients were divided into three body-weight groups A (< 60 kg), B (60-80 kg), and C (> 80 kg). The tube current was randomized prospectively in low weight group A, either 125 mA or 150 mA, in middle and high weight groups B and C, 150, 175 or 200 mA, with a tube revolution time of one second. The noise was measured in liver, skeleton muscle, fat tissue, and bladder content for evaluation of image quality. Results: The bodyweight groups differ significantly in noise, e.g., in the liver (150 mA): group A: 15.8 HU, group B: 18.9 HU, group C: 21.5 HU. The increase of tube current (150, 175, 200 mA) within a body weight group resulted in a minor decrease of noise (18.9 HU, 17.6 HU, 17.5 HU, respectively, in group B). There is a good correlation of noise with body weight, body mass index and body cross section, but not with body size. Conclusion: A body weight adjusted reduction of tube current is possible without an increase of noise.
引用
收藏
页码:52 / 56
页数:5
相关论文
共 11 条
[1]  
BERNHARDT JH, 1995, BUNDESMINISTERIUM UM, P179
[2]  
BROOKS R A, 1976, Medical Physics (Woodbury), V3, P237, DOI 10.1118/1.594240
[3]  
GELEIJNS J, 1995, RADIAT PROT DOSIM, V57, P129
[4]  
Greess H, 1999, ROFO-FORTSCHR RONTG, V170, P246
[5]   Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers [J].
Kalender, WA ;
Wolf, H ;
Suess, C ;
Gies, M ;
Greess, H ;
Bautz, WA .
EUROPEAN RADIOLOGY, 1999, 9 (02) :323-328
[6]   RADIATION-DOSE REDUCTION IN CT OF THE PEDIATRIC PELVIS [J].
KAMEL, IR ;
HERNANDEZ, RJ ;
MARTIN, JE ;
SCHLESINGER, AE ;
NIKLASON, LT ;
GUIRE, KE .
RADIOLOGY, 1994, 190 (03) :683-687
[7]  
Lehmann K J, 1997, Aktuelle Radiol, V7, P156
[8]   Low-dose spiral CT:: applicability to paediatric chest imaging [J].
Rogalla, P ;
Stöver, B ;
Scheer, I ;
Juran, R ;
Gaedicke, G ;
Hamm, B .
PEDIATRIC RADIOLOGY, 1999, 29 (08) :565-569
[9]  
ROGALLA P, 1997, KONTRASTE, V11, P10
[10]   Radiation dose and image quality in spiral computed tomography:: multicentre evaluation at six institutions [J].
Scheck, RJ ;
Coppenrath, EM ;
Kellner, MW ;
Lehmann, KJ ;
Rock, C ;
Rieger, J ;
Rothmeier, L ;
Schweden, F ;
Bäuml, AA ;
Hahn, K .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (847) :734-744