Low-dose spiral CT:: applicability to paediatric chest imaging

被引:68
作者
Rogalla, P
Stöver, B
Scheer, I
Juran, R
Gaedicke, G
Hamm, B
机构
[1] Humboldt Univ, Charite Hosp, Dept Diagnost & Intervent Radiol, D-10117 Berlin, Germany
[2] Humboldt Univ, Charite Hosp, Dept Pediat, D-10117 Berlin, Germany
关键词
D O I
10.1007/s002470050648
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background. Spiral CT of the chest is an imaging technique with unequivocal indications and proven higher sensitivity and specificity than conventional chest Xrays. However, particularly in children, attempts should be made to reduce radiation exposure to a minimum. Objective. To evaluate whether a low-dose technique in spiral CT scanning results in adequate diagnostic information. Materials and methods. In a prospective study, 27 children (range 3 weeks to 14 years, mean 7 years) underwent a low-dose CT examination of the chest for various indications. The tube energy was 12.5 mAs (n = 5), 25 mAs (n = 17), 50 mAs (n = 3), or 75 mAs (n = 2) per slice. Two radiologists evaluated, in consensus, the CT scans with respect to their diagnostic value and comparison was made with 20 standard-dose chest CT examinations of adults (175 mAs per slice, mean age 56 years) with respect to technical image quality (noise and artefacts). In a second part of the study, dose measurements were carried out by means of exposing thermoluminescent dosimeters attached to a water/air phantom simulating a child's chest. Results. All low-dose CT scans were of diagnostic image quality and no additional studies were necessary. The average image noise was significantly higher than in standard-dose CT examinations (SD 39.5 compared with 12.5 for unenhanced soft tissue, P < 0.01), but did not hinder accurate diagnosis. Artefacts were exclusively due to patient motion. Radiation exposure per slice was approx. 4 mGy at 25 mAs and 34 mGy at 250 mAs, regardless of slice thickness. Conclusions. For all indications in paediatric CT scanning of the chest, low-dose technique provides adequate image quality without loss of diagnostic information. The radiation exposure is approximately 5-20 % of a standard-dose CT.
引用
收藏
页码:565 / 569
页数:5
相关论文
共 17 条
[1]   FEASIBILITY OF HIGH-RESOLUTION, LOW-DOSE CHEST CT IN EVALUATING THE PEDIATRIC CHEST [J].
AMBROSINO, MM ;
GENIESER, NB ;
ROCHE, KJ ;
KAUL, A ;
LAWRENCE, RM .
PEDIATRIC RADIOLOGY, 1994, 24 (01) :6-10
[2]  
Bernhardt JU, 1995, Z MED PHYS, V5, P33
[3]   HELICAL CT - PRINCIPLES AND TECHNICAL CONSIDERATIONS [J].
BRINK, JA ;
HEIKEN, JP ;
WANG, G ;
MCENERY, KW ;
SCHLUETER, FJ ;
VANNIER, MW .
RADIOGRAPHICS, 1994, 14 (04) :887-893
[4]   COMPARISON OF SPIRAL-ACQUISITION COMPUTED-TOMOGRAPHY AND CONVENTIONAL COMPUTED-TOMOGRAPHY IN THE ASSESSMENT OF PULMONARY METASTATIC DISEASE [J].
COLLIE, DA ;
WRIGHT, AR ;
WILLIAMS, JR ;
HASHEMIMALAYERI, B ;
STEVENSON, AJM ;
TURNBULL, CM .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (797) :436-444
[5]   PULMONARY NODULE - EVALUATION WITH SPIRAL VOLUMETRIC CT [J].
COSTELLO, P ;
ANDERSON, W ;
BLUME, D .
RADIOLOGY, 1991, 179 (03) :875-876
[6]   COMPARISON OF HELICAL AND CONVENTIONAL CHEST CT IN THE UNCOOPERATIVE PEDIATRIC-PATIENT [J].
COX, TD ;
WHITE, KS ;
WEINBERGER, E ;
EFFMANN, EL .
PEDIATRIC RADIOLOGY, 1995, 25 (05) :347-349
[7]   A COMPARISON OF RADIATION-DOSES TO THE BREAST IN COMPUTED TOMOGRAPHIC CHEST EXAMINATIONS FOR 2 SCANNING PROTOCOLS [J].
EVANS, SH ;
DAVIS, R ;
COOKE, J ;
ANDERSON, W .
CLINICAL RADIOLOGY, 1989, 40 (01) :45-46
[8]   A COMPARISON OF CONVENTIONAL AND SPIRAL CT - AN EXPERIMENTAL-STUDY ON THE DETECTION OF SPHERICAL LESIONS [J].
KALENDER, WA ;
POLACIN, A ;
SUSS, C .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) :167-176
[9]  
KRAMER SS, 1996, SPIRAL CT PEDIAT CHE, P73
[10]   HIGH-RESOLUTION CT OF THE CHEST - RADIATION-DOSE [J].
MAYO, JR ;
JACKSON, SA ;
MULLER, NL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :479-481