COMPARISON OF HELICAL AND CONVENTIONAL CHEST CT IN THE UNCOOPERATIVE PEDIATRIC-PATIENT

被引:10
作者
COX, TD
WHITE, KS
WEINBERGER, E
EFFMANN, EL
机构
[1] Department of Radiology, Children's Hospital and Medical Center, Seattle, 98105, WA, CH-69
关键词
D O I
10.1007/BF02021699
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The objective of this study was to compare the quality of conventional and helical computed tomography (CT) images in children unable to breath-hold. Sixteen patients (age range 1.1-7.5 years) underwent both conventional and helical chest CT on a General Electric HiSpeed Advantage scanner at a mean study interval of 3.8 months. Conventional 0.6-s scans were reconstructed with standard algorithm while 1.0-s helical studies were reconstructed with standard and bone algorithms. Three blinded observers retrospectively evaluated the images. There was no significant difference in motion, image sharpness and anatomic resolution for helical and conventional scans reconstructed with standard algorithm. Furthermore, image sharpness (P<0.001) and visibility of bronchi (P<0.001) were improved when helical images were reconstructed with bone algorithm. We conclude that motion artifact severity, image sharpness and anatomic resolution for helical and conventional 0.6-s chest CT are similar when the images are reconstructed with an identical algorithm. Helical CT may be preferable because of the faster examination times and the ability to reconstruct overlapping images as an adjunct for problem solving. Also, with the scanner used, bone algorithm reconstruction can be employed to improve image sharpness and anatomic resolution.
引用
收藏
页码:347 / 349
页数:3
相关论文
共 12 条
  • [1] HIGH-RESOLUTION CT OF PARENCHYMAL LUNG-DISEASE - PRECISE CORRELATION WITH HISTOLOGIC-FINDINGS
    BESSIS, L
    CALLARD, P
    GOTHEIL, C
    BIAGGI, A
    GRENIER, P
    [J]. RADIOGRAPHICS, 1992, 12 (01) : 45 - 58
  • [2] BRASCH RC, 1988, RADIOL CLIN N AM, V26, P277
  • [3] PULMONARY NODULE - EVALUATION WITH SPIRAL VOLUMETRIC CT
    COSTELLO, P
    ANDERSON, W
    BLUME, D
    [J]. RADIOLOGY, 1991, 179 (03) : 875 - 876
  • [4] DAVIS SD, 1991, RADIOLOGY, V180, P1
  • [5] IMAGE QUALITY IN DYNAMIC CT - A CLINICAL DISCUSSION
    FOLEY, WD
    [J]. RADIOGRAPHICS, 1993, 13 (01) : 225 - 233
  • [6] SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION
    KALENDER, WA
    SEISSLER, W
    KLOTZ, E
    VOCK, P
    [J]. RADIOLOGY, 1990, 176 (01) : 181 - 183
  • [7] SPIRAL CT OF THE LUNGS - OPTIMAL TECHNIQUE AND RESOLUTION COMPARED WITH CONVENTIONAL CT
    PARANJPE, DV
    BERGIN, CJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (03) : 561 - 567
  • [8] PULMONARY NODULES - DETECTION WITH THICK-SECTION SPIRAL CT VERSUS CONVENTIONAL CT
    REMYJARDIN, M
    REMY, J
    GIRAUD, F
    MARQUETTE, CH
    [J]. RADIOLOGY, 1993, 187 (02) : 513 - 520
  • [9] PEDIATRIC PULMONARY NODULES - A COMPARISON OF COMPUTED-TOMOGRAPHY, THORACOTOMY FINDINGS AND HISTOLOGY
    ROBERTSON, PL
    BOLDT, DW
    DECAMPO, JF
    [J]. CLINICAL RADIOLOGY, 1988, 39 (06) : 607 - 610
  • [10] WHITE KS, 1994, SOC PEDIATRIC RADIOL