RADIATION-DOSE REDUCTION IN CT OF THE PEDIATRIC PELVIS

被引:65
作者
KAMEL, IR
HERNANDEZ, RJ
MARTIN, JE
SCHLESINGER, AE
NIKLASON, LT
GUIRE, KE
机构
[1] UNIV MICHIGAN,DEPT RADIOL,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN,DEPT BIOSTAT,ANN ARBOR,MI 48109
关键词
CHILDREN; GENITOURINARY SYSTEM; COMPUTED TOMOGRAPHY (CT); IN INFANTS; AND CHILDREN; PELVIC ORGANS; CT; PELVIS; RADIATIONS; EXPOSURE; TO PATIENTS AND PERSONNEL;
D O I
10.1148/radiology.190.3.8115611
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine whether a lower radiation dose technique can be used for computed tomography (CT) of the pediatric pelvis without significant loss of diagnostic image quality. MATERIALS AND METHODS: Thirty-six pediatric patients underwent CT at 80 mAs (experimental group), and 42 underwent CT at 240 mAs (control group). Anatomic details, image quality, and the degree of confidence in reaching a diagnosis were graded on a scale of 1 (poor) to 4 (excellent). RESULTS: The difference in perceived image quality between the experimental and control groups was not statistically significant. The mean scores for scans evaluated by the first reader were 3.88 for the experimental group and 3.92 for the control group (P =.2804). The mean scores for the second reader were 3.78 and 3.77 for the experimental and control groups, respectively (P =.8131). CONCLUSION: A substantial dose reduction can be achieved if pelvic CT is performed at 80 mAs, without a recognizable deterioration of diagnostic image quality.
引用
收藏
页码:683 / 687
页数:5
相关论文
共 13 条
[1]   STUDIES OF MORTALITY OF A-BOMB SURVIVORS .6. MORTALITY AND RADIATION-DOSE, 1950-1974 [J].
BEEBE, GW ;
KATO, H ;
LAND, CE .
RADIATION RESEARCH, 1978, 75 (01) :138-201
[2]  
BROOKS R A, 1976, Medical Physics (Woodbury), V3, P237, DOI 10.1118/1.594240
[3]   ACTIVE BONE-MARROW DISTRIBUTION AS A FUNCTION OF AGE IN HUMANS [J].
CRISTY, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (03) :389-400
[4]   PEDIATRIC-PATIENT EXPOSURES FROM CT EXAMINATIONS - GE CT/T 9800 SCANNER [J].
FEARON, T ;
VUCICH, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (04) :805-809
[5]   NORMALIZED PEDIATRIC ORGAN-ABSORBED DOSES FROM CT EXAMINATIONS [J].
FEARON, T ;
VUCICH, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (01) :171-174
[6]   DOSIMETRY OF COMPUTERIZED-TOMOGRAPHY IN THE EVALUATION OF HIP-DYSPLASIA [J].
GUYER, B ;
SMITH, DS ;
CADY, RB ;
BASSANO, DA ;
LEVINSOHN, EM .
SKELETAL RADIOLOGY, 1984, 12 (02) :123-127
[7]  
HAAGA JR, 1979, AM J ROENTGENOL, V133, P633
[8]   THE EFFECT OF MAS VARIATION UPON COMPUTED-TOMOGRAPHY IMAGE QUALITY AS EVALUATED BY INVIVO AND INVITRO STUDIES [J].
HAAGA, JR ;
MIRALDI, F ;
MACINTYRE, W ;
LIPUMA, JP ;
BRYAN, PJ ;
WIESEN, E .
RADIOLOGY, 1981, 138 (02) :449-454
[9]   DETECTION OF LOW-CONTRAST LESIONS IN COMPUTED BODY TOMOGRAPHY - EXPERIMENTAL-STUDY OF SIMULATED LESIONS [J].
MEANEY, TF ;
RAUDKIVI, U ;
MCINTYRE, WJ ;
GALLAGHER, JH ;
HAAGA, JR ;
HAVRILLA, TR ;
REICH, NE .
RADIOLOGY, 1980, 134 (01) :149-154
[10]   RADIATION-DOSE REDUCTION IN PEDIATRIC CT [J].
ROBINSON, AE ;
HILL, EP ;
HARPEN, MD .
PEDIATRIC RADIOLOGY, 1986, 16 (01) :53-54