Dose reduction in CT by anatomically adapted tube current modulation. 1. Simulation studies

被引:262
作者
Gies, M
Kalender, WA
Wolf, H
Suess, C
Madsen, MT
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91045 Erlangen, Germany
[2] Univ Iowa, Dept Radiol, Iowa City, IA USA
关键词
computed tomography (CT); dose; tube current modulation; simulation studies;
D O I
10.1118/1.598779
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Tube current modulation governed by x-ray attenuation during CT (computed tomography) acquisition can lead to noise reduction which in turn can be used to achieve patient dose reduction without loss in image quality. The potential of this technique was investigated in simulation studies calculating both noise amplitude levels and noise distribution in CT images. The dependence of noise on the modulation function, amplitude of modulation, shape and size of the object, and possible phase shift between attenuation and modulation function were examined. Both sinusoidal and attenuation-based control functions were used to modulate tube current. Noise reduction was calculated for both ideal systems and for real systems with limited modulation amplitude, Dose reductions up to 50% can be achieved depending on the phantom geometry and tube current modulation function. Attenuation-based tube current modulation yields substantially higher reduction than fixed-shape modulation functions. Optimal results are obtained when the current is modulated as a function of the square root of attenuation. A modulation amplitude of at least 90% should be available to exploit the potential of these techniques. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)03011-4].
引用
收藏
页码:2235 / 2247
页数:13
相关论文
共 8 条
[1]  
Bernhardt JU, 1995, Z MED PHYS, V5, P33
[2]   NOISE DUE TO PHOTON-COUNTING STATISTICS IN COMPUTED X-RAY TOMOGRAPHY [J].
CHESLER, DA ;
RIEDERER, SJ ;
PELC, NJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (01) :64-74
[3]  
*GE MED SYST, 1994, CT HISP ADV RP SYST, V15, P12
[4]   THE EFFECT OF MAS VARIATION UPON COMPUTED-TOMOGRAPHY IMAGE QUALITY AS EVALUATED BY INVIVO AND INVITRO STUDIES [J].
HAAGA, JR ;
MIRALDI, F ;
MACINTYRE, W ;
LIPUMA, JP ;
BRYAN, PJ ;
WIESEN, E .
RADIOLOGY, 1981, 138 (02) :449-454
[5]   Image quality and dose in computed tomography [J].
Jurik, AG ;
Jessen, KA ;
Hansen, J .
EUROPEAN RADIOLOGY, 1997, 7 (01) :77-81
[6]   RADIATION-DOSE REDUCTION IN CT OF THE PEDIATRIC PELVIS [J].
KAMEL, IR ;
HERNANDEZ, RJ ;
MARTIN, JE ;
SCHLESINGER, AE ;
NIKLASON, LT ;
GUIRE, KE .
RADIOLOGY, 1994, 190 (03) :683-687
[7]   RADIATION-DOSE IN CT [J].
ROTHENBERG, LN ;
PENTLOW, KS .
RADIOGRAPHICS, 1992, 12 (06) :1225-1243
[8]  
Verdun FR, 1996, EUR RADIOL, V6, P485