Cardiac spiral dual-source CT with high pitch: a feasibility study

被引:53
作者
Ertel, Dirk [1 ]
Lell, Michael M. [2 ]
Harig, Frank [3 ]
Flohr, Thomas [4 ]
Schmidt, Bernhard [4 ]
Kalender, Willi A. [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Radiol, D-91052 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Ctr Cardiac Surg, D-91052 Erlangen, Germany
[4] Siemens Healthcare, Forchheim, Germany
关键词
Dual-source CT; Cardiac imaging; Image quality; Dose; High pitch; TOMOGRAPHY CORONARY-ANGIOGRAPHY; MULTISLICE COMPUTED-TOMOGRAPHY; IMAGE QUALITY; RADIATION-EXPOSURE; SHOOT MODE; PERFORMANCE; HEART; VALIDATION; MODULATION; REDUCTION;
D O I
10.1007/s00330-009-1503-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Increase of pitch in spiral CT decreases data acquisition time; dual-source CT (DSCT) systems provide improved temporal resolution. We evaluated the combination of these two features. Measurements were performed using a commercial DSCT system equipped with prototype software allowing pitch factors from p=0.35 to 3.0. We measured slice sensitivity profiles as a function of pitch to assess spatial resolution in the z-direction and the contrast of structures moved periodically to measure temporal resolution. Additionally we derived modulation transfer functions to provide objective parameters; both spatial and temporal resolution were essentially unchanged even at high pitch. CT of the cardiac region of three pigs was performed at p=3.0. In vivo CT images confirmed good image quality; direct comparison with standard low-pitch phase-correlated CT image datasets showed no significant difference. For a normalized z-axis acquisition of 12 cm, the corresponding effective dose value was 2.0 mSv for the high-pitch CT protocol. We conclude that spiral DSCT imaging with a pitch of 3.0 can provide unimpaired image quality with respect to spatial and temporal resolution. Applications to cardiac and thoracic imaging with effective dose below 1 mSv are possible.
引用
收藏
页码:2357 / 2362
页数:6
相关论文
共 23 条
[1]   Current and future status on cardiac computed tomography imaging for diagnosis and risk stratification [J].
Achenbach, S .
JOURNAL OF NUCLEAR CARDIOLOGY, 2005, 12 (06) :703-713
[2]   Dual-source cardiac computed tomography: image quality and dose considerations [J].
Achenbach, Stephan ;
Anders, Katharina ;
Kalender, Willi A. .
EUROPEAN RADIOLOGY, 2008, 18 (06) :1188-1198
[3]   Generation XXX - Pornography acceptance and use among emerging adults [J].
Carroll, Jason S. ;
Padilla-Walker, Laura M. ;
Nelson, Larry J. ;
Olson, Chad D. ;
Barry, Carolyn McNamara ;
Madsen, Stephanie D. .
JOURNAL OF ADOLESCENT RESEARCH, 2008, 23 (01) :6-30
[4]   Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography [J].
Coles, DR ;
Smail, MA ;
Negus, IS ;
Wilde, P ;
Oberhoff, M ;
Karsch, KR ;
Baumbach, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (09) :1840-1845
[5]   Effects of Adaptive Section Collimation on Patient Radiation Dose in Multisection Spiral CT [J].
Deak, Paul D. ;
Langner, Oliver ;
Lell, Michael ;
Kalender, Willi A. .
RADIOLOGY, 2009, 252 (01) :140-147
[6]   Modulation transfer function-based assessment of temporal resolution:: Validation for single-and dual-source CT [J].
Ertel, Dirk ;
Kroeber, Evelyn ;
Kyriakou, Yiannis ;
Langner, Oliver ;
Kalender, Willi A. .
RADIOLOGY, 2008, 248 (03) :1013-1017
[7]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[8]   Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates [J].
Hausleiter, J ;
Meyer, T ;
Hadamitzky, M ;
Huber, E ;
Zankl, M ;
Martinoff, S ;
Kastrati, A ;
Schömig, A .
CIRCULATION, 2006, 113 (10) :1305-1310
[9]   Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation [J].
Jakobs, TF ;
Becker, CR ;
Ohnesorge, B ;
Flohr, T ;
Suess, C ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2002, 12 (05) :1081-1086
[10]   Dual-source CT cardiac imaging: initial experience [J].
Johnson, Thorsten R. C. ;
Nikolaou, Konstantin ;
Wintersperger, Bernd J. ;
Leber, Alexander W. ;
von Ziegler, Franz ;
Rist, Carsten ;
Buhmann, Sonja ;
Knez, Andreas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1409-1415