Dual-source CT cardiac imaging: initial experience

被引:258
作者
Johnson, Thorsten R. C.
Nikolaou, Konstantin
Wintersperger, Bernd J.
Leber, Alexander W.
von Ziegler, Franz
Rist, Carsten
Buhmann, Sonja
Knez, Andreas
Reiser, Maximilian F.
Becker, Christoph R.
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
[2] Univ Munich, Med Clin 1, Dept Cardiol, D-81377 Munich, Germany
关键词
dual source CT; coronary CT angiography; coronary artery disease; heart valves; left ventricular function;
D O I
10.1007/s00330-006-0298-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The relation of heart rate and image quality in the depiction of coronary arteries, heart valves and myocardium was assessed on a dual-source computed tomography system (DSCT). Coronary CT angiography was performed on a DSCT (Somatom Definition, Siemens) with high concentration contrast media (Iopromide, Ultravist 370, Schering) in 24 patients with heart rates between 44 and 92 beats per minute. Images were reconstructed over the whole cardiac cycle in 10% steps. Two readers independently assessed the image quality with regard to the diagnostic evaluation of right and left coronary artery, heart valves and left ventricular myocardium for the assessment of vessel wall changes, coronary stenoses, valve morphology and function and ventricular function on a three point grading scale. The image quality ratings at the optimal reconstruction interval were 1.24 +/- 0.42 for the right and 1.09 +/- 0.27 for the left coronary artery. A reconstruction of diagnostic systolic and diastolic images is possible for a wide range of heart rates, allowing also a functional evaluation of valves and myocardium. Dual-source CT offers very robust diagnostic image quality in a wide range of heart rates. The high temporal resolution now also makes a functional evaluation of the heart valves and myocardium possible.
引用
收藏
页码:1409 / 1415
页数:7
相关论文
共 25 条
  • [1] Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience
    Achenbach, S
    Ropers, D
    Kuettner, A
    Flohr, T
    Ohnesorge, B
    Bruder, H
    Theessen, H
    Karakaya, M
    Daniel, WG
    Bautz, W
    Kalender, WA
    Anders, K
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) : 331 - 335
  • [2] Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography
    Achenbach, S
    Giesler, T
    Ropers, D
    Ulzheimer, S
    Anders, K
    Wenkel, E
    Pohle, K
    Kachelriess, M
    Derlien, H
    Kalender, WA
    Daniel, WG
    Bautz, W
    Baum, U
    [J]. INVESTIGATIVE RADIOLOGY, 2003, 38 (02) : 119 - 128
  • [3] Becker CR, 2000, RADIOLOGE, V40, P118, DOI 10.1007/s001170050019
  • [4] Detection of coronary artery stenoses with multislice helical CT angiography
    Becker, CR
    Knez, A
    Leber, A
    Treede, H
    Ohnesorge, B
    Schoepf, UJ
    Reiser, MF
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (05) : 750 - 755
  • [5] First performance evaluation of a dual-source CT (DSCT) system
    Flohr, TG
    McCollough, CH
    Bruder, H
    Petersilka, M
    Gruber, K
    Süss, C
    Grasruck, M
    Stierstorfer, K
    Krauss, B
    Raupach, R
    Primak, AN
    Küttner, A
    Achenbach, S
    Becker, C
    Kopp, A
    Ohnesorge, BM
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (02) : 256 - 268
  • [6] 16-MDCT coronary angiography versus invasive coronary angiography in acute chest pain syndrome: A blinded prospective study
    Ghersin, E
    Litmanovich, D
    Dragu, R
    Rispler, S
    Lessick, J
    Ofer, A
    Brook, OR
    Gruberg, L
    Beyar, R
    Engel, A
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (01) : 177 - 184
  • [7] Myocardial bridging - Noninvasive diagnosis with multidetector CT
    Goitein, O
    Lacomis, JM
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (02) : 238 - 240
  • [8] Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates
    Hausleiter, J
    Meyer, T
    Hadamitzky, M
    Huber, E
    Zankl, M
    Martinoff, S
    Kastrati, A
    Schömig, A
    [J]. CIRCULATION, 2006, 113 (10) : 1305 - 1310
  • [9] Multidetector-row cardiac CT: diagnostic value of calcium scoring and CT coronary angiography in patients with symptomatic, but atypical, chest pain
    Herzog, C
    Britten, M
    Balzer, JO
    Mack, MG
    Zangos, S
    Ackermann, H
    Schaechinger, V
    Schaller, S
    Flohr, T
    Vogl, TJ
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (02) : 169 - 177
  • [10] ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality
    Hong, C
    Becker, CR
    Huber, A
    Schoepf, UJ
    Ohnesorge, B
    Knez, A
    Brüning, R
    Reiser, MF
    [J]. RADIOLOGY, 2001, 220 (03) : 712 - 717