Modulation transfer function-based assessment of temporal resolution:: Validation for single-and dual-source CT

被引:15
作者
Ertel, Dirk [1 ]
Kroeber, Evelyn [1 ]
Kyriakou, Yiannis [1 ]
Langner, Oliver [1 ]
Kalender, Willi A. [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
关键词
D O I
10.1148/radiol.2482072173
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to determine a manufacturer-independent quality assurance measurement for temporal resolution with a three-dimensional cardiac motion robot; validation was with single-source (SS) and dual-source (DS) computed tomography (CT). Image acquisition was performed by using standard cardiac protocols. Image contrast-based modulation transfer function (MTF) was assessed as function of time. For motion frequency of 60 beats per minute, MTF slightly decreased by 14% and 6% for SS CT and DS CT, respectively. For higher frequencies, a stronger decrease of MTF (eg, by 50% [SS CT] and 18% [DS CT] at 120 beats per minute) was detected. Effect of manufacturer's adaptive bisegment algorithm for SS CT and corresponding resonance effects of rotation time and heart rate were quantified. The robot-based approach is a reproducible, objective way to assess temporal resolution; it allows practical measurement of temporal resolution and comparison of CT scanners and protocols. (C) RSNA, 2008.
引用
收藏
页码:1013 / 1017
页数:5
相关论文
共 15 条
[1]   Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[2]   Image reconstruction and image quality evaluation for a 16-slice CT scanner [J].
Flohr, T ;
Stierstorfer, K ;
Bruder, H ;
Simon, J ;
Polacin, A ;
Schaller, S .
MEDICAL PHYSICS, 2003, 30 (05) :832-845
[3]   Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart [J].
Flohr, T ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :907-923
[4]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[5]   COMPUTERIZED TRANSVERSE AXIAL SCANNING (TOMOGRAPHY) .1. DESCRIPTION OF SYSTEM [J].
HOUNDFIELD, GN .
BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (552) :1016-1022
[6]   Multi-slice helical CT: Scan and reconstruction [J].
Hu, H .
MEDICAL PHYSICS, 1999, 26 (01) :5-18
[7]   ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart [J].
Kachelriess, M ;
Ulzheimer, S ;
Kalender, WA .
MEDICAL PHYSICS, 2000, 27 (08) :1881-1902
[8]   Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart [J].
Kachelriess, M ;
Kalender, WA .
MEDICAL PHYSICS, 1998, 25 (12) :2417-2431
[9]   Multithreaded cardiac CT [J].
Kachelriess, Marc ;
Knaup, Michael ;
Kalender, Willi A. .
MEDICAL PHYSICS, 2006, 33 (07) :2435-2447
[10]  
KALENDER WA, 2005, COMPUTED TOMOGRAPHY