Cross-calibration of body-composition techniques against dual-energy X-ray absorptiometry in young children

被引:263
作者
Goran, MI [1 ]
Driscoll, P [1 ]
Johnson, R [1 ]
Nagy, TR [1 ]
Hunter, G [1 ]
机构
[1] UNIV VERMONT,DEPT NUTR SCI,BURLINGTON,VT 05405
关键词
skinfold-thickness measurements; dual-energy X-ray absorptiometry; bioelectrical resistance; obesity; body composition; fat mass; fat-free mass; lean mass;
D O I
10.1093/ajcn/63.3.299
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 [营养与食品卫生学];
摘要
Using dual-energy X-ray absorptiometry (DXA) as a standard method for determining body composition in children, we evaluated the accuracy of skinfold-thickness measurements (with the Slaughter et al equations, which are based on triceps and calf skinfold-thickness measurements), bioelectrical resistance (BR; with the Kushner et al equations and age-specific hydration constants), and other clinical measurements (individual skinfold thicknesses and body mass index) for the assessment of body fat in children. We studied a heterogenous group of 49 boys and 49 girls, aged 6.6 +/- 1.4 y and weighing 24.1 +/- 5.9 kg. Fat mass estimated by DXA was significantly lower than fat mass measured by skinfold thickness, even though fat mass measurements by these two techniques were strongly related to each other. Fat mass estimated by DXA was also significantly lower than fat mass measured by BR, and the model R(2) and SEE were not as strong as for the skinfold-thickness technique. Fat mass estimated by DXA also correlated with other clinical indexes such as triceps skinfold thickness, body mass index, body weight, and subscapular skinfold thickness. In forward-regression analysis, subscapular skinfold thickness, body weight, triceps skinfold thickness, sex, and height(2)/resistance estimated the value for fat mass measured by DXA with a model R(2) Of 0.91 and an SEE of 0.94 kg fat mass. These studies suggest that existing techniques for assessing body fat in children may be inaccurate. We provide new anthropometric equations based on the use of DXA as a criterion that provide accurate and precise measures of body fat and fat-free mass in white children aged 4-9 y. This approach provides estimates of body fat standardized to a known laboratory standard of chemical analysis of carcasses.
引用
收藏
页码:299 / 305
页数:7
相关论文
共 20 条
[1]
VALIDATION AND APPLICATION OF DUAL-ENERGY X-RAY ABSORPTIOMETRY TO MEASURE BONE MASS AND BODY-COMPOSITION IN SMALL INFANTS [J].
BRUNTON, JA ;
BAYLEY, HS ;
ATKINSON, SA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 58 (06) :839-845
[2]
DEURENBERG P, 1990, EUR J CLIN NUTR, V44, P261
[3]
ACCURACY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR BODY-COMPOSITION MEASUREMENTS IN CHILDREN [J].
ELLIS, KJ ;
SHYPAILO, RJ ;
PRATT, JA ;
POND, WG .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1994, 60 (05) :660-665
[4]
TOTAL-BODY ELECTRICAL-CONDUCTIVITY MEASUREMENTS - EFFECTS OF BODY-COMPOSITION AND GEOMETRY [J].
FIOROTTO, ML ;
COCHRAN, WJ ;
FUNK, RC ;
SHENG, HP ;
KLISH, WJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (04) :R794-R800
[5]
BODY-COMPOSITION OF REFERENCE CHILDREN FROM BIRTH TO AGE 10 YEARS [J].
FOMON, SJ ;
HASCHKE, F ;
ZIEGLER, EE ;
NELSON, SE .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1982, 35 (05) :1169-1175
[6]
ESTIMATING BODY-COMPOSITION OF YOUNG-CHILDREN BY USING BIOELECTRICAL RESISTANCE [J].
GORAN, MI ;
KASKOUN, MC ;
CARPENTER, WH ;
POEHLMAN, ET ;
RAVUSSIN, E ;
FONTVIEILLE, AM .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (04) :1776-1780
[7]
GORAN MI, IN PRESS OBES RES
[8]
JANZ KF, 1993, MED SCI SPORT EXER, V25, P1070
[9]
IS THE IMPEDANCE INDEX (HT2/R) SIGNIFICANT IN PREDICTING TOTAL-BODY WATER [J].
KUSHNER, RF ;
SCHOELLER, DA ;
FJELD, CR ;
DANFORD, L .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1992, 56 (05) :835-839
[10]
LOHMAN TG, 1986, EXERCISE SPORT SCI R, V14, P325