Conductometric urea sensor. Use of additional membranes for the improvement of its analytical characteristics

被引:53
作者
Jdanova, AS
Poyard, S
Soldatkin, AP
JaffrezicRenault, N
Martelet, C
机构
[1] ECOLE CENT LYON,LAB PHYSICOCHIM INTERFACES,CNRS,URA 404,F-69131 ECULLY,FRANCE
[2] NATL ACAD SCI UKRAINE,INST MOLEC BIOL & GENET,KIEV 252143,UKRAINE
关键词
conductimetry; biosensors; urease; urea; additional membranes; Nafion membrane; PW membrane; permselectivity;
D O I
10.1016/0003-2670(95)00548-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Urea-sensitive enzymatic conductometric biosensors based on interdigitated gold electrodes were prepared by cross-linking urease with bovine serum albumin in a saturated glutaraldehyde vapour on the sensor chips. Additional Nafion or PVP (poly(4-vinylpyridine-co-styrene)) membranes were deposited on top of the urea microsensor by a spin-coating process. The main analytical characteristics (dynamic range, buffer concentration sensitivity) of these urea-sensitive microconductometric devices were not significantly modified by the use of Nafion additional membranes. Better results were obtained for sensors coated with PVP additional membranes: their operational storage stability and reproducibility are promising for further applications, especially in the biomedical field.
引用
收藏
页码:35 / 40
页数:6
相关论文
共 14 条
[1]   MULTIANALYTE MINIATURE CONDUCTANCE BIOSENSOR [J].
CULLEN, DC ;
SETHI, RS ;
LOWE, CR .
ANALYTICA CHIMICA ACTA, 1990, 231 (01) :33-40
[2]  
DZYADEVICH SV, 1994, ELECTROANAL, V6, P752
[3]  
DZYADEVICH SV, 1994, 5 INT M CHEM SENS RO, V1, P189
[4]  
HENDJI AMN, 1994, SENSOR ACTUAT B-CHEM, V21, P123
[5]   MULTIANALYTE MICROELECTRONIC BIOSENSORS [J].
HIN, BFYY ;
SETHI, RS ;
LOWE, CR .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :550-554
[6]   CHIP BIOSENSORS ON THIN-FILM METAL-ELECTRODES [J].
HINTSCHE, R ;
MOLLER, B ;
DRANSFELD, I ;
WOLLENBERGER, U ;
SCHELLER, F ;
HOFFMANN, B .
SENSORS AND ACTUATORS B-CHEMICAL, 1991, 4 (3-4) :287-291
[7]  
Korpan Ya. I., 1994, Ukrainskii Biokhimicheskii Zhurnal, V66, P78
[8]   CONDUCTOMETRIC TRANSDUCERS FOR ENZYME-BASED BIOSENSORS [J].
MIKKELSEN, SR ;
RECHNITZ, GA .
ANALYTICAL CHEMISTRY, 1989, 61 (15) :1737-1742
[9]   THIN-FILM CONDUCTOMETRIC BIOSENSORS FOR GLUCOSE AND UREA DETERMINATION [J].
SHULGA, AA ;
SOLDATKIN, AP ;
ELSKAYA, AV ;
DZYADEVICH, SV ;
PATSKOVSKY, SV ;
STRIKHA, VI .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (03) :217-223
[10]   REMOVING THE INFLUENCE OF BUFFER CONCENTRATION ON THE RESPONSE OF ENZYME FIELD-EFFECT TRANSISTORS BY USING ADDITIONAL MEMBRANES [J].
SHULGA, AA ;
STRIKHA, VI ;
SOLDATKIN, AP ;
ELSKAYA, AV ;
MAUPAS, H ;
MARTELET, C ;
CLECHET, P .
ANALYTICA CHIMICA ACTA, 1993, 278 (02) :233-236