High-resolution fast spin echo imaging of the human brain at 4.7 T: Implementation and sequence characteristics

被引:48
作者
Thomas, DL
De Vita, E
Roberts, S
Turner, R
Yousry, TA
Ordidge, RJ
机构
[1] UCL, Wellcome Trust High Field MR Res Lab, Dept Med Phys & Bioengn, London WC1N 3AR, England
[2] MR Res Syst, Guildford, Surrey, England
[3] Inst Neurol, London WC1N 3BG, England
基金
英国惠康基金;
关键词
high-field FSE; feathering; T(2)-weighted MRI; structural MRI; high-field MR;
D O I
10.1002/mrm.20106
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work, a number of important issues associated with fast spin echo (FSE) imaging of the human brain at 4.7 T are addressed. It is shown that FSE enables the acquisition of images with high resolution and good tissue contrast throughout the brain at high field strength. By employing an echo spacing (ES) of 22 ms, one can use large flip angle refocusing pulses (162degrees) and a low acquisition bandwidth (50 kHz) to maximize the signal-to-noise ratio (SNR). A new method of phase encode (PE) ordering (called "feathering") designed to reduce image artifacts is described, and the contributions of RF (B(1)) inhomogeneity, different echo coherence pathways, and magnetization transfer (MT) to FSE signal intensity and contrast are investigated. B(1) inhomogeneity is measured and its effect is shown to be relatively minor for high-field FSE, due to the self-compensating characteristics of the sequence. Thirty-four slice data sets (slice thickness = 2 mm; in-plane resolution = 0.469 mm; acquisition time = 11 min 20 s) from normal volunteers are presented, which allow visualization of brain anatomy in fine detail. This study demonstrates that high-field FSE produces images of the human brain with high spatial resolution, SNR, and tissue contrast, within currently prescribed power deposition guidelines. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:1254 / 1264
页数:11
相关论文
共 37 条
[1]   Radio frequency magnetic field mapping of a 3 tesla birdcage coil: Experimental and theoretical dependence on sample properties [J].
Alecci, M ;
Collins, CM ;
Smith, MB ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :379-385
[2]  
Barfuss H, 1990, NMR Biomed, V3, P31, DOI 10.1002/nbm.1940030106
[3]  
BRIDGES JF, 1988, Patent No. 4751464
[4]   THE FIELD-DEPENDENCE OF NMR IMAGING .1. LABORATORY ASSESSMENT OF SIGNAL-TO-NOISE RATIO AND POWER DEPOSITION [J].
CHEN, CN ;
SANK, VJ ;
COHEN, SM ;
HOULT, DI .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) :722-729
[5]   Compensating for B1 inhomogeneity using active transmit power modulation [J].
Clare, S ;
Alecci, M ;
Jezzard, P .
MAGNETIC RESONANCE IMAGING, 2001, 19 (10) :1349-1352
[6]  
Clare S., 2002, P 10 ANN M ISMRM HON, P1465
[7]   SIGNAL-TO-NOISE AND CONTRAST IN FAST SPIN-ECHO (FSE) AND INVERSION RECOVERY FSE IMAGING [J].
CONSTABLE, RT ;
SMITH, RC ;
GORE, JC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (01) :41-47
[8]   FACTORS INFLUENCING CONTRAST IN FAST SPIN-ECHO MR IMAGING [J].
CONSTABLE, RT ;
ANDERSON, AW ;
ZHONG, J ;
GORE, JC .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :497-511
[9]   High resolution MRI of the brain at 4.7 Tesla using fast spin echo imaging [J].
De Vita, E ;
Thomas, DL ;
Roberts, S ;
Parkes, HG ;
Turner, R ;
Kinchesh, P ;
Shmueli, K ;
Yousry, TA ;
Ordidge, RJ .
BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (909) :631-637
[10]   Optimization of 3-D MP-RAGE sequences for structural brain imaging [J].
Deichmann, R ;
Good, CD ;
Josephs, O ;
Ashburner, J ;
Turner, R .
NEUROIMAGE, 2000, 12 (01) :112-127