Evaluation of the Kinect™ sensor for 3-D kinematic measurement in the workplace

被引:285
作者
Dutta, Tilak [1 ]
机构
[1] Toronto Rehabil Inst, Technol R&D Team, Toronto, ON M5G 2A2, Canada
基金
加拿大创新基金会;
关键词
Portable motion capture; Kinect; Kinematics;
D O I
10.1016/j.apergo.2011.09.011
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Recording posture and movement is important for determining risk of musculoskeletal injury in the workplace, but existing motion capture systems are not suited for field work. Estimates of the 3-D relative positions of four 0.10 m cubes from the Kinect were compared to estimates from a Vicon motion capture system to determine whether the hardware sensing components were sensitive enough to be used as a portable 3-D motion capture system for workplace ergonomic assessments. The root-mean-squared errors (SD) were 0.0065 m (0.0048 m), 0.0109 m (0.0059 m), 0.0057 m (0.0042 m) in the x, y and z directions (with x axis to the right, y axis away from the sensor and z axis upwards). These data were collected over a range of 1.0-3.0 m from the device covering a field of view of 54.0 degrees horizontally and 39.1 degrees vertically. Requirements for software, hardware and subject preparation were also considered to determine the usability of the Kinect in the field. (C) 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.
引用
收藏
页码:645 / 649
页数:5
相关论文
共 15 条
[1]   Determining the minimum sampling rate needed to accurately quantify cumulative spine loading from digitized video [J].
Andrews, DM ;
Callaghan, JP .
APPLIED ERGONOMICS, 2003, 34 (06) :589-595
[2]   Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo [J].
Benoit, Daniel L. ;
Ramsey, Dan K. ;
Lamontagne, Mario ;
Xu, Lanyi ;
Wretenberg, Per ;
Renstrom, Per .
GAIT & POSTURE, 2006, 24 (02) :152-164
[3]  
Best R., 2006, COMPUTATIONAL INTELL
[4]   The static accuracy and calibration of inertial measurement units for 3D orientation [J].
Brodie, M. A. ;
Walmsley, A. ;
Page, W. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2008, 11 (06) :641-648
[5]  
Burrus N., 2011, KINECT RGB DEMO V0 4
[6]  
Freedman B., 2010, Primesense LTD patent, Patent No. [US 2010/0118123 Al, 20100118123, 20100118123 A1]
[7]  
Kreylos O., 2010, KINECT HACKING
[8]   Effects of Camera Switching on Fine Accuracy in a Motion Capture System [J].
Kuxhaus, Laurel ;
Schimoler, Patrick J. ;
Vipperman, Jeffrey S. ;
Miller, Mark Carl .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (01)
[9]   A comparison of low back kinetic estimates obtained through posture matching, rigid link modeling and an EMG-assisted model [J].
Parkinson, R. J. ;
Bezaire, M. ;
Callaghan, J. P. .
APPLIED ERGONOMICS, 2011, 42 (05) :644-651
[10]  
Shpunt A., 2010, Patent No. [20100020078, 2010020078]