Effects of Camera Switching on Fine Accuracy in a Motion Capture System

被引:10
作者
Kuxhaus, Laurel [2 ,3 ]
Schimoler, Patrick J. [1 ,3 ]
Vipperman, Jeffrey S. [1 ,2 ]
Miller, Mark Carl [1 ,2 ,3 ]
机构
[1] Univ Pittsburgh, Dept Mech Engn & Mat Sci, Pittsburgh, PA 15261 USA
[2] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15261 USA
[3] Allegheny Gen Hosp, Orthopaed Biomech Res Lab, Pittsburgh, PA 15212 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2009年 / 131卷 / 01期
关键词
biomechanics; biomedical measurement; biomedical optical imaging; cameras; image motion analysis; random noise; RELATIVE MOTION; TRACKING; MOVEMENT; PERFORMANCE; DESIGN;
D O I
10.1115/1.3002910
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
When using optical motion capture systems, increasing the number of cameras improves the visibility. However, the software used to deal with the information fusion from multiple cameras may compromise the accuracy of the system due to camera dropout, which can vary with time. In cadaver studies of radial head motion, increasing the number of cameras used by the motion capture system seemed to decrease the accuracy of the measurements. This study investigates the cause. The hypothesis was that errors in position can be induced when markers are obscured from and then restored to a camera's viewable range, as can happen in biomechanical studies. Accuracy studies quantified the capabilities of the motion capture system with precision translation and rotation movements. To illustrate the effect that abrupt perceived changes in a marker's position can have on the calculation of radial head travel, simulated motion experiments were performed. In these studies, random noise was added to simulated data, which obscured the resultant path of motion. Finally, camera-blocking experiments were performed in which precise movements were measured with a six-camera Vicon system and the errors between the actual and perceived motion were computed. During measurement, cameras were selectively blocked and restored to view. The maximum errors in translation and rotation were 3.7 mm and 0.837 deg, respectively. Repeated measures analysis of variance (ANOVAs) (alpha=0.05) confirmed that the camera-blocking influenced the results. Taken together, these results indicate that camera-switching can affect the observation of fine movements using a motion analysis system with a large number of cameras. One solution is to offer opportunity for user interaction in the software to choose the cameras used for each instant of time.
引用
收藏
页数:6
相关论文
共 35 条
[1]  
Abu-Faraj ZO, 1997, P ANN INT IEEE EMBS, V19, P1831, DOI 10.1109/IEMBS.1997.757087
[2]   Tracking densely moving markers [J].
Borghese, NA ;
Rigiroli, P .
FIRST INTERNATIONAL SYMPOSIUM ON 3D DATA PROCESSING VISUALIZATION AND TRANSMISSION, 2002, :682-685
[3]  
Butler A.L., 2005, ANN M AM SOC SURG HA
[4]   Tracking human motion in structured environments using a distributed-camera system [J].
Cai, Q ;
Aggarwal, JK .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1999, 21 (11) :1241-1247
[5]   Automatic tracking of human motion in indoor scenes across multiple synchronized video streams [J].
Cai, Q ;
Aggarwal, JK .
SIXTH INTERNATIONAL CONFERENCE ON COMPUTER VISION, 1998, :356-362
[6]   Surface-marker cluster design criteria for 3-D bone movement reconstruction [J].
Cappozzo, A ;
Cappello, A ;
DellaCroce, U ;
Pensalfini, F .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (12) :1165-1174
[7]   Position and orientation in space of bones during movement: Experimental artefacts [J].
Cappozzo, A ;
Catani, F ;
Leardini, A ;
Benedetti, MG ;
DellaCroce, U .
CLINICAL BIOMECHANICS, 1996, 11 (02) :90-100
[8]   Technical note: validation of a motion analysis system for measuring the relative motion of the intermediate component of a tripolar total hip arthroplasty prosthesis [J].
Chen, QS ;
Lazennec, JY ;
Guyen, O ;
Kinbrum, A ;
Berry, DJ ;
An, KN .
MEDICAL ENGINEERING & PHYSICS, 2005, 27 (06) :505-512
[9]   Human movement analysis using stereophotogrammetry - Part 2: Instrumental errors [J].
Chiari, L ;
Della Croce, U ;
Leardini, A ;
Cappozzo, A .
GAIT & POSTURE, 2005, 21 (02) :197-211
[10]   Multiple camera tracking of interacting and occluded human motion [J].
Dockstader, SL ;
Tekalp, AM .
PROCEEDINGS OF THE IEEE, 2001, 89 (10) :1441-1455