Fluorimetric determination of aluminium in water by sequential injection through column extraction

被引:21
作者
Brach-Papa, C
Coulomb, B
Branger, C
Margaillan, A
Théraulaz, F
Van Loot, P
Boudenne, JL
机构
[1] Univ Aix Marseille 1, EA 2678, Lab Chim & Environm, F-13331 Marseille 3, France
[2] Univ Toulon & Var, ISITV, MFS EA 1356, Lab Chim Appl, F-83162 La Valette Du Var, France
关键词
aluminium; solid phase extraction; chelating resin; fluorimetry; drinking water;
D O I
10.1007/s00216-003-2464-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fluorimetric procedure for the determination of aluminium with matrix removal in drinking water is proposed. The system is based both on the solid phase extraction of aluminium on a new chelating resin (XAD-4 modified by grafting salicylic acid) and the fluorimetric detection of a complex formed between 8-hydroxyquinoline-5-sulfonic acid (HQS) and Al(III), after elution of the resin by hydrochloric acid. The sorption and elution of aluminium were studied in both competitive and noncompetitive conditions, varying pH, flow-rates, volume and concentration of reagents, as well as time contact. The optimised procedure allows determination of Al3+ at the sub-ppb level (LOD: 0.2 mug L-1 for 1 ml of sample) within a working range of 0.2-500 mug L-1. The analytical procedure was successfully employed for the determination of aluminium in drinking water during and after flocculation/coagulation treatment processes.
引用
收藏
页码:1652 / 1658
页数:7
相关论文
共 45 条
[1]   Flow-injection solvent extraction with and without phase separation - Fluorimetric determination of aluminium in water [J].
Alonso, A ;
Almendral, MJ ;
Porras, MJ ;
Curto, Y ;
de Maria, CG .
ANALYTICA CHIMICA ACTA, 2001, 447 (1-2) :211-217
[2]  
[Anonymous], 1997, ALUMINIUM ENV HLTH C
[3]  
Becerra E, 1999, LAB ROBOTICS AUTOMAT, V11, P131, DOI 10.1002/(SICI)1098-2728(1999)11:3<131::AID-LRA2>3.0.CO
[4]  
2-9
[5]   Acute aluminum encephalopathy in a dialysis center caused by a cement mortar water distribution pipe [J].
Berend, K ;
van der Voet, G ;
Boer, WH .
KIDNEY INTERNATIONAL, 2001, 59 (02) :746-753
[6]   Analytical methodologies for aluminium speciation in environmental and biological samples - a review [J].
Bi, SP ;
Yang, XD ;
Zhang, FP ;
Wang, XL ;
Zou, GW .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (08) :984-996
[7]   On-line separation and spectrophotometric determination of low levels of aluminum in high-salt content samples: application to analysis of hemodialysis fluids [J].
Bohrer, D ;
Gioda, A ;
Binotto, R ;
do Nascimento, PC .
ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) :163-169
[9]   Modification of poly(styrene-co-divinylbenzene) resin by grafting on an aluminium selective ligand [J].
Boudenne, JL ;
Boussetta, S ;
Brach-Papa, C ;
Branger, C ;
Margaillan, A ;
Théraulaz, F .
POLYMER INTERNATIONAL, 2002, 51 (10) :1050-1057
[10]   Spectrofluorimetric determination of aluminum in drinking waters by sequential injection analysis [J].
Brach-Papa, C ;
Coulomb, B ;
Boudenne, JL ;
Cerda, V ;
Theraulaz, F .
ANALYTICA CHIMICA ACTA, 2002, 457 (02) :311-318