EMG sensor location: Does it influence the ability to detect differences in muscle contraction conditions?

被引:31
作者
Mercer, JA
Bezodis, N
DeLion, D
Zachry, T
Rubley, MD
机构
[1] Univ Nevada, Dept Kinesiol, Las Vegas, NV 89154 USA
[2] Univ Bath, Sch Hlth, Dept Exercise & Sport Sci, Bath BA2 7AY, Avon, England
关键词
muscle activity; biceps brachii; isotonic; isometric;
D O I
10.1016/j.jelekin.2005.07.002
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Even though it is well known that electromyography (EMG) characteristics are influenced by electrode placement it is common to use a single pair of sensors per muscle for EMG. This study was designed to determine if the ability to distinguish between contraction conditions was influenced by sensor location. Subjects (n = 10; 27 +/- 5.3 years; 82 +/- 13.4 kg; 178 +/- 7.1 cm) completed six elbow flexor conditions: three isometric contraction intensities (100% maximum effort, 80%, 50%) and three isotonic contraction intensities (heavy weight, 80% and 50% of the weight). Three pairs of electrodes were placed centrally, medially and laterally on the biceps brachii belly in line with the muscle fibers. Isometric contractions were held for 5 s, with the middle 3 s analyzed. Isotonic exercises included five repetitions of elbow flexion-extension, with the middle three repetitions analyzed. Average EMG (EMG(AVG)) root mean square EMG (EMG(RMS)) and mean power frequency (MPF) were calculated for each extracted data set. Dependent variables were analyzed using 2 (contraction type) x 3 (intensity) repeated measures ANOVAs per sensor. EMGAVG was influenced by the interaction between contraction type and intensity for all sensors (p < 0.05). EMG(RMS) as well as MPF were influenced by the interaction between contraction type and intensity for the lateral and central leads (p < 0.05) but not the medial leads (p > 0.05). Different conclusions could have been reached from the same experiment due to different sensor locations. These differences were primarily related to comparing contraction types (i.e., isotonic vs. isometric). (C) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:198 / 204
页数:7
相关论文
共 12 条
[1]   The use of surface electromyography in biomechanics [J].
De Luca, CJ .
JOURNAL OF APPLIED BIOMECHANICS, 1997, 13 (02) :135-163
[2]   Influence of interelectrode distance and force level on the spectral parameters of surface electromyographic recordings from the lumbar muscles [J].
Elfving, B ;
Liljequist, D ;
Mattsson, E ;
Németh, G .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2002, 12 (04) :295-304
[3]   Location of innervation zones of sternocleidomastoid and scalene muscles - a basis for clinical and research electromyography applications [J].
Falla, D ;
Dall'Alba, P ;
Rainoldi, A ;
Merletti, R ;
Jull, G .
CLINICAL NEUROPHYSIOLOGY, 2002, 113 (01) :57-63
[4]   Influence of anatomical, physical, and detection-system parameters on surface EMG [J].
Farina, D ;
Cescon, C ;
Merletti, R .
BIOLOGICAL CYBERNETICS, 2002, 86 (06) :445-456
[5]   Effect of joint angle on EMG variables in leg and thigh muscles [J].
Farina, D ;
Merletti, R ;
Nazzaro, M ;
Caruso, I .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2001, 20 (06) :62-71
[6]   Development of recommendations for SEMG sensors and sensor placement procedures [J].
Hermens, HJ ;
Freriks, B ;
Disselhorst-Klug, C ;
Rau, G .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2000, 10 (05) :361-374
[7]   Variability of some SEMG parameter estimates with electrode location [J].
Hogrel, JY ;
Duchene, J ;
Marini, JF .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1998, 8 (05) :305-315
[8]   Estimating maximal EMG amplitude for the trapezius muscle: On the optimization of experimental procedure and electrode placement for improved reliability and increased signal amplitude [J].
Jensen, C ;
Vasseljen, O ;
Westgaard, RH .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1996, 6 (01) :51-58
[9]   Influence of motoneuron firing synchronization on SEMG characteristics in dependence of electrode position [J].
Kleine, BU ;
Stegeman, DF ;
Mund, D ;
Anders, C .
JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (04) :1588-1599
[10]   Geometrical factors in surface EMG of the vastus medialis and lateralis muscles [J].
Rainoldi, A ;
Nazzaro, M ;
Merletti, R ;
Farina, D ;
Caruso, I ;
Gaudenti, S .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2000, 10 (05) :327-336