Examining the association between surface bioburden and frequently touched sites in intensive care

被引:63
作者
Adams, C. E. [1 ]
Smith, J. [2 ]
Watson, V. [1 ]
Robertson, C. [3 ,4 ,5 ]
Dancer, S. J. [2 ,6 ]
机构
[1] NHS Lanarkshire, Dept Anaesthesia, Hairmyres Hosp, E Kilbride, Lanark, Scotland
[2] NHS Lanarkshire, Dept Microbiol, Hairmyres Hosp, E Kilbride, Lanark, Scotland
[3] Univ Strathclyde, Dept Math & Stat, Glasgow, Lanark, Scotland
[4] Hlth Protect Scotland, Glasgow, Lanark, Scotland
[5] Int Prevent Res Inst, Lyon, France
[6] Edinburgh Napier Univ, Sch Appl Sci, Edinburgh, Midlothian, Scotland
关键词
Hospital cleaning; Intensive care unit; Healthcare environment; Hand-touch sites; Microbial reservoirs; RESISTANT STAPHYLOCOCCUS-AUREUS; ENVIRONMENTAL SURFACES; HOSPITALS; INFECTION; CONTACT; DECONTAMINATION; ACQUISITION; STANDARDS; HYGIENE; HANDS;
D O I
10.1016/j.jhin.2016.11.002
中图分类号
R1 [预防医学、卫生学];
学科分类号
100235 [预防医学];
摘要
Background: Critical care patients are at increased risk of infection. Near-patient surfaces act as reservoirs of microbial soil, which may contain pathogens. Aim: To correlate soil levels with hand-touch frequency of near-patient sites in an intensive care unit (ICU). Methods: Five sites around each bed in a 10-bed ICU were screened for total microbial soil (cfu/cm(2)) and Staphylococcus aureus every month for 10 months. Selected sites were infusion pump and cardiac monitor, left and right bedrails, and bed table. Ten 1 h covert audits of hand-touch frequency of these sites were performed in order to provide an average hand-touch count, which was modelled against soil levels obtained from microbiological screening. Findings: Seven of 10 staphylococci were found in conjunction with gross contamination of a specific site (P = 0.005) and the same proportion from three most frequently touched sites (bedrails and bed table). There was a linear association between four sites demonstrating gross microbial contamination (>12 cfu/cm(2)) and mean number of hand-touch counts (P = 0.08). The bed table was handled most but was not the most contaminated site. We suspected that customary placement of alcohol gel containers on bed tables may have reduced microbiological yield. Removing the gel container from one table confirmed its inhibitory effect on microbial contamination after rescreening (19% vs 50% > 12 cfu/ cm(2): P - 0.007). Conclusion: Surface bioburden at near-patient sites in ICU is associated with hand-contact frequencies by staff and visitors. This supports the need for targeted hygienic cleaning in a high-risk healthcare environment. (C) 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 20 条
[1]
Evaluation of the Efficacy of a Conventional Cleaning Regimen in Removing Methicillin-Resistant Staphylococcus aureus From Contaminated Surfaces in an Intensive Care Unit [J].
Aldeyab, Mamoon A. ;
McElnay, James C. ;
Elshibly, Salah M. ;
Hughes, Carmel M. ;
McDowell, David A. ;
McMahon, M. Ann S. ;
Scott, Michael G. ;
Kearney, Mary P. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2009, 30 (03) :304-306
[2]
Acquisition of nosocomial pathogens on hands after contact with environmental surfaces near hospitalized patients [J].
Bhalla, A ;
Pultz, NJ ;
Gries, DM ;
Ray, AJ ;
Eckstein, EC ;
Aron, DC ;
Donskey, CJ .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2004, 25 (02) :164-167
[3]
Bogusz A., 2013, Healthcare Infection, V18, P3, DOI 10.1071/HI12063
[4]
An evaluation of patient area cleaning in 3 hospitals using a novel targeting methodology [J].
Carling, Philip C. ;
Briggs, Janet ;
Hylander, Deborah ;
Perkins, Jeannette .
AMERICAN JOURNAL OF INFECTION CONTROL, 2006, 34 (08) :513-519
[5]
Hand-touch contact assessment of high-touch and mutual-touch surfaces among healthcare workers, patients, and visitors [J].
Cheng, V. C. C. ;
Chau, P. H. ;
Lee, W. M. ;
Ho, S. K. Y. ;
Lee, D. W. Y. ;
So, S. Y. C. ;
Wong, S. C. Y. ;
Tai, J. W. M. ;
Yuen, K. Y. .
JOURNAL OF HOSPITAL INFECTION, 2015, 90 (03) :220-225
[6]
The role of environmental cleaning in the control of hospital-acquired infection [J].
Dancer, S. J. .
JOURNAL OF HOSPITAL INFECTION, 2009, 73 (04) :378-385
[7]
How do we assess hospital cleaning? A proposal for microbiological standards for surface hygiene in hospitals [J].
Dancer, SJ .
JOURNAL OF HOSPITAL INFECTION, 2004, 56 (01) :10-15
[8]
Monitoring environmental cleanliness on two surgical wards [J].
Dancer, Stephanie J. ;
White, Liza ;
Robertson, Chris .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH, 2008, 18 (05) :357-364
[9]
Importance of the environment in meticillin-resistant Staphylococcus aureus acquisition:: the case for hospital cleaning [J].
Dancer, Stephanie J. .
LANCET INFECTIOUS DISEASES, 2008, 8 (02) :101-113
[10]
Dos and don'ts for hospital cleaning [J].
Dancer, Stephanie J. .
CURRENT OPINION IN INFECTIOUS DISEASES, 2016, 29 (04) :415-423