Sol-gel derived nanoporous cerium oxide film for application to cholesterol biosensor

被引:198
作者
Ansari, Anees A. [1 ]
Kaushik, A. [1 ]
Solanki, P. R. [1 ]
Malhotra, B. D. [1 ]
机构
[1] Natl Phys Lab, Biomol Elect & Conducting Polymer Res Grp, New Delhi 110012, India
关键词
sol-gel; cerium oxide; nanoporous; cholesterol oxidase; electrochemical biosensor;
D O I
10.1016/j.elecom.2008.06.003
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Cholesterol oxidase (ChOx) has been immobilized onto sol-gel derived nano-structured cerium oxide (NS-CeO2) film deposited on indium-tin-oxide (ITO) coated glass substrate. Phase identification of sol-gel NS-CeO2 film carried out using X-ray diffraction (XRD) yields reflection peak at 29.4 degrees corresponding to (111) plane with oriented crystallite (34 nm) along c-axis normal to the substrate. Electrochemical studies reveal that NS-CeO2 provides electroactive surface for the loading of ChOx and enhances electron transfer rate in the ChOx/NS-CeO2/ITO bioelectrocle. The low value of Michaelis-Menten constant (K-m) obtained as 2.08 mM indicates enhanced ChOx affinity to cholesterol. The observed results show application of sol-gel derived NS-CeO2 for biosensing without any functionalization. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1246 / 1249
页数:4
相关论文
共 15 条
  • [1] Recent advances in cholesterol biosensor
    Arya, Sunil K.
    Datta, Monika
    Malhotra, Bansi D.
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 23 (07) : 1083 - 1100
  • [2] Electrochemical impedance immunosensor based on three-dimensionally ordered macroporous gold film
    Chen, Xiaojun
    Wang, Yuanyuan
    Zhou, Jinjun
    Yan, Wei
    Li, Xinghua
    Zhu, Jun-Jie
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (06) : 2133 - 2140
  • [3] Amperometric biosensors employing an insoluble oxidant as an interference-removing agent
    Choi, SH
    Lee, SD
    Shin, JH
    Ha, J
    Nam, H
    Cha, GS
    [J]. ANALYTICA CHIMICA ACTA, 2002, 461 (02) : 251 - 260
  • [4] A nano-porous CeO2/chitosan composite film as the immobilization matrix for colorectal cancer DNA sequence-selective electrochemical biosensor
    Feng, Ke-Jun
    Yang, Yun-Hui
    Wang, Zhi-Jie
    Jiang, Jian-Hui
    Shen, Guo-Li
    Yu, Ru-Qin
    [J]. TALANTA, 2006, 70 (03) : 561 - 565
  • [5] Direct electrochemistry and electrocatalysis of horseradish peroxidase immobilized in sol-gel-derived tin oxide/gelatin composite films
    Jia, NQ
    Zhou, Q
    Liu, L
    Yan, MM
    Jiang, ZY
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 580 (02) : 213 - 221
  • [6] Zinc oxide nanoparticles-chitosan composite film for cholesterol biosensor
    Khan, Raju
    Kaushik, Ajeet
    Solanki, Pratima R.
    Ansari, Anees A.
    Pandey, Manoj K.
    Malhotra, B. D.
    [J]. ANALYTICA CHIMICA ACTA, 2008, 616 (02) : 207 - 213
  • [7] Kouassi G. K., 2005, J NANOBIOTECHNOL, V3, P1, DOI DOI 10.1186/1477-3155-3-1
  • [8] A novel multivalent nanomaterial based hydrogen peroxide sensor
    Mehta, Anjum
    Patil, Swanand
    Bang, Hyungseok
    Cho, Hyoung J.
    Seal, Sudipta
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2007, 134 (01) : 146 - 151
  • [9] GLUCOSE BIOSENSOR BASED ON A SOL-GEL-DERIVED PLATFORM
    NARANG, U
    PRASAD, PN
    BRIGHT, FV
    RAMANATHAN, K
    KUMAR, ND
    MALHOTRA, BD
    KAMALASANAN, MN
    CHANDRA, S
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (19) : 3139 - 3144
  • [10] Synthesis and properties of cerium and titanium oxide thin coatings for corrosion protection of 304 stainless steel
    Nazeri, A
    TrzaskomaPaulette, PP
    Bauer, D
    [J]. JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 1997, 10 (03) : 317 - 331