Comparison of lung tissue concentrations of nebulized ceftazidime in ventilated piglets: ultrasonic versus vibrating plate nebulizers

被引:33
作者
Ferrari, Fabio [2 ]
Liu, Zhi-Hai [3 ]
Lu, Qin [1 ,4 ]
Becquemin, Marie-Helene [5 ]
Louchahi, Kamel [6 ]
Aymard, Guy [7 ]
Marquette, Charles-Hugo [8 ,9 ]
Rouby, Jean-Jacques [4 ]
机构
[1] La Pitie Salpetriere Hosp, Dept Anesthesia & Crit Care, Reanimat Chirurg Polyvalente Pierre Viars, F-75013 Paris, France
[2] Univ Estadual Paulista, Fac Med, Dept Anesthesiol, Botucatu, SP, Brazil
[3] Zhejiang Univ, Sch Med, Dept Emergency Med, Affiliated Hosp 2, Hangzhou 310027, Peoples R China
[4] Univ Paris 06, La Pitie Salpetriere Hosp, Dept Anesthesiol & Crit Care Med, AP HP,Surg Intens Care Unit Pierre Viars, Paris, France
[5] Denis Diderot Univ, La Salpetriere Hosp, AP HP, Dept Resp Physiol, F-2397 Paris, France
[6] Avicenne Hosp, AP HP, Dept Pharmacol, Bobigny, France
[7] La Pitie Salpetriere Hosp, AP HP, Dept Pharmacol, Paris, France
[8] Univ Rech Expt, Dept Hosp, Lille, France
[9] Univ Lille, INSERM U416, Inst Pasteur, Lille, France
关键词
ultrasonic; vibrating plate; nebulizer; nebulization of antibiotics; lung tissue concentration;
D O I
10.1007/s00134-008-1126-4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To compare the efficiency of an Aeroneb Pro vibrating plate and an Atomisor MegaHertz ultrasonic nebulizer for providing ceftazidime distal lung deposition. Design: In vitro experiments. One gram of cetazidime was nebulized in respiratory circuits and mass median aerodynamic diameter of particles generated by ultrasonic and vibrating plate nebulizers was compared using a laser velocimeter. In vivo experiments. Lung tissue concentrations and extrapulmonary depositions were measured in ten anesthetized ventilated piglets with healthy lungs that received 1 g of ceftazidime by nebulization with either an ultrasonic (n = 5), or a vibrating plate (n = 5) nebulizer. Setting: A two-bed Experimental Intensive Care Unit of a University School of Medicine. Intervention: Following sacrifice, 5 subpleural specimens were sampled in dependent and nondependent lung regions for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography. Measurements and results: Mass median aerodynamic diameters generated by both nebulizers were similar with more than 95% of the particles between 0.5 and 5 mu m. Lung tissue concentrations were 553 +/- 123 [95% confidence interval: 514-638] mu g g(-1) using ultrasonic nebulizer, and 452 +/- 172 [95% confidence interval: 376-528] mu g g(-1) using vibrating plate nebulizers (NS). Extrapulmonary depositions were, respectively, of 38 +/- 5% (ultrasonic) and 34 +/- 4% (vibrating plate) (NS). Conclusions: Vibrating plate nebulizer is comparable to ultrasonic nebulizers for ceftazidime nebulization. It may represent a new attractive technology for inhaled antibiotic therapy.
引用
收藏
页码:1718 / 1723
页数:6
相关论文
共 21 条
[1]  
[Anonymous], RESP CARE
[2]  
[Anonymous], PRINCIPLES PRACTICE
[3]   Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Lijmer, JG ;
Moher, D ;
Rennie, D ;
de Vet, HCW .
ANNALS OF INTERNAL MEDICINE, 2003, 138 (01) :40-44
[4]   ENDOTRACHEAL AND AEROSOL ADMINISTRATIONS OF CEFTAZIDIME IN PATIENTS WITH NOSOCOMIAL PNEUMONIA - PHARMACOKINETICS AND ABSOLUTE BIOAVAILABILITY [J].
BRESSOLLE, F ;
DELACOUSSAYE, JE ;
AYOUB, R ;
FABRE, D ;
GOMENI, R ;
SAISSI, G ;
ELEDJAM, JJ ;
GALTIER, M .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1992, 36 (07) :1404-1411
[5]   Effective inhaled drug administration to mechanically ventilated patients [J].
Dhand, Rajiv ;
Mercier, Emmanuelle .
EXPERT OPINION ON DRUG DELIVERY, 2007, 4 (01) :47-61
[6]  
Dhand Rajiv, 2002, Respir Care, V47, P1406
[7]   Aerosol deposition in neonatal ventilation [J].
Dubus, JC ;
Vecellio, L ;
De Monte, M ;
Fink, JB ;
Grimbert, D ;
Montharu, J ;
Valat, C ;
Behan, N ;
Diot, P .
PEDIATRIC RESEARCH, 2005, 58 (01) :10-14
[8]   Influence of lung aeration on pulmonary concentrations of nebulized and intravenous amikacin in ventilated piglets with severe bronchopneumonia [J].
Elman, M ;
Goldstein, I ;
Marquette, CH ;
Wallet, F ;
Lenaour, G ;
Rouby, JJ .
ANESTHESIOLOGY, 2002, 97 (01) :199-206
[9]  
Faurisson F, 1996, REV MAL RESPIR, V13, P155
[10]   Reconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors [J].
Fink, JB ;
Dhand, R ;
Grychowski, J ;
Fahey, PJ ;
Tobin, MJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (01) :63-68